DANGER
Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause injury. The appliance area must be kept free and clear of combustible material at all times.
All installation and service on FRYMASTER equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel.
Service may be obtained by contacting your local Factory Authorized Service Center.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored.
This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors.
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.
In Australia
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.
WARNING
Do not block the area around the base or under the fryers.
2.2Power Requirements
MODEL | VOLTAGE | PHASE | WIRE | MINIMUM WIRE | AMPS | |
| SIZE | |||||
SERVICE |
| (per leg) | ||||
|
|
| AWG | (mm) | ||
|
|
|
|
| ||
FPPH14 | 208 | Single | 3 | 3 | (5.83) | 68 |
FPPH14 | 208 | 3 | 3 | 6 | (4.11) | 39 |
FPPH14 | 240 | Single | 3 | 4 | (5.19) | 59 |
FPPH14 | 240 | 3 | 3 | 6 | (4.11) | 34 |
FPPH14 | 480 | Single | 3 | 8 | (3.26) | 30 |
FPPH14 | 480 | 3 | 3 | 8 | (2.59) | 17 |
FPPH14 | 220/380 | 3 | 4 | 6 | (4.11) | 21 |
FPPH14 | 240/415 | 3 | 4 | 6 | (4.11) | 20 |
FPPH14 | 230/400 | 3 | 4 | 6 | (4.11) | 21 |
FPPH17 | 208 | 3 | 3 | 6 | (4.11) | 48 |
FPPH17 | 240 | 3 | 3 | 6 | (4.11) | 41 |
FPPH17 | 480 | 3 | 3 | 6 | (4.11) | 21 |
FPPH17 | 220/380 | 3 | 4 | 6 | (4.11) | 26 |
FPPH17 | 240/415 | 3 | 4 | 6 | (4.11) | 24 |
FPPH17 | 230/400 | 3 | 4 | 6 | (4.11) | 25 |
FPPH22 | 208 | 3 | 3 | 4 | (5.19) | 61 |
FPPH22 | 240 | 3 | 3 | 4 | (5.19) | 53 |
FPPH22 | 480 | 3 | 3 | 6 | (4.11) | 27 |
FPPH22 | 220/380 | 3 | 4 | 6 | (4.11) | 34 |
FPPH22 | 240/415 | 3 | 4 | 6 | (4.11) | 31 |
FPPH22 | 230/400 | 3 | 4 | 6 | (4.11) | 32 |