•“EMERGENCY STOP”
If the “EMERGENCY STOP”
c.PROBABLE CAUSES;
1)ANOTHER “EMERGENCY STOP” (E-Stop) BUTTON
2)A DISCONNECT PLUG
3)FAULTY SWITCH
4)WIRING BACK TO TB1
d.POSSIBLE SOLUTIONS;
1)Verify that ALL other “EMERGENCY STOP”
2)Verify that ALL of the Pendant’s disconnect plugs are indeed connected. The disconnect plugs are for removal of the Pendant arm for shipping.
3)With the control voltage off, open pendant assembly and check switch using an OHM meter, replace if defective.
4)Locate terminals 14 and 15 on TB1 on the bottom of the electrical enclosure. Open their associated disconnects and place an OHM meter across these terminals. Push the “EMERGENCY STOP”
•If “YES,” wiring from the pendant to TB1 is correct, check wiring on the main electrical panel, then retest.
•If “NO,” wiring from the TB1 is incorrect. Check wiring using the appropriate wiring diagrams listed above, and retest.
E.TEMPERATURE SENSING
INTRODUCTION
There is one (1) temperature sensing and controlling device in the
The following information will provide a means to respond to “Temperature Sensing” malfunctions, and verify ALL its electrical signals. Refer to the following diagrams placement and wiring information.
•
•
•