MLE-130 II (80 Kw Electric)
Reversing, 3ø
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
B.Circuit breakers are
C.Circuit breakers for
OVEN SIZE | SERVICE |
| WIRE | APPROX. | ||
PHASE | AMP DRAW | |||||
(Kw) | VOLTAGE | SERVICE | ||||
|
|
| ||||
| 60 Hz | 50 Hz | ||||
|
|
|
| |||
80 | 208 | 3ø | 3 | 236 | 236 | |
|
|
|
|
|
| |
80 | 230/240 | 3ø | 3 | 209 | 209 | |
|
|
|
|
|
| |
80 |
| 3ø | 3/4 | 126 | ||
|
|
|
|
|
| |
80 | 416 | 3ø | 3/4 | 118 | ||
|
|
|
|
|
| |
80 | 480 | 3ø | 3/4 | 103 | ||
|
|
|
|
|
| |
80 | 575 | 3ø | 3 | 87 | ||
|
|
|
|
|
|
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
25