3.Exhaust Transition Piece (Gas and Electric Only!)

WARNING

An exhaust duct transition piece is shipped inside of the dryer’s tumbler and must be installed on the dryer’s exhaust duct, with the hardware provided, BEFORE location venting is connected to the dryer.

THIS EXHAUST DUCT TRANSITION PIECE

MUST BE INSTALLED FIRST!

Failure to observe this installation requirement may result in damage to the dryer, create a FIRE HAZARD and will VOID the manufacturer’s warranty.

012999JEV-GS/cj

P/N: 114092

a. Inside the basket (tumbler) of this dryer is an exhaust transition piece that must be installed on the outlet of the exhaust before any further venting is connected:

1) Remove the exhaust transition piece from the basket (tumbler) and place it on the exhaust outlet.

2) Using the screws provided, secure the exhaust transition piece to the dryer.

NOTE: It is recommended that this joint be taped as well as ALL other duct joints to prevent moisture and lint from escaping into the building.