American Dryer Corp ML-130DR Steam Damper Air System Connections, Air Requirements, Air Pressure

Models: ML-130 III ML-130DR

1 28
Download 28 pages 36.88 Kb
Page 19
Image 19
Steam Damper Air System Connections

Steam Damper Air System Connections

The steam dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air 0.75 cfh (0.02 cmh). The air connection is made to the steam damper solenoid valve, which is located at the rear inner top area of the dryer just above the electric service relay box (refer to the illustration on the following page).

Air Requirements

Compressed Air Supply

Air Pressure

 

 

 

Normal

80 psi

5.51 bar

Minimum Supply

70 psi

4.82 bar

Maximum Supply

90 psi

6.21 bar

 

 

 

Shaded areas are stated in metric equivalents

Air Connection

Air connection to system – 1/8” N.P.T.

No air regulation or filtration is provided with the dryer. External regulation/filtration of 0.75 cfh (0.02 cmh) @ 80 psi (5.51 bar) must be provided. It is suggested that a regulator/ filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved.

Steam Damper System Operation

The steam damper, as shown in the illustration below, allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn directly into the tumbler, allowing a rapid cool down.

Diagram 1 – shows the damper in the heating (open) mode, allowing heat into the tumbler.

Diagram 2 – shows the damper in the cool down (closed) mode, pulling ambient air directly into the tumbler without passing through the coils.

NOTE: With the dryer off or with no air supply, the damper is in the cool down mode as shown in Diagram 2.

113335 - 12

www.amdry.com

19

Page 19
Image 19
American Dryer Corp ML-130DR Steam Damper Air System Connections, Air Requirements, Compressed Air Supply, Air Pressure