113604-4 www.amdry.com 5
Machine Info Coin Vault
Hours
Serial #
Software Rev
Program Setup Dry Mode
Coin Dry Mode
Free Dry Mode
Control Settings
Language Multi Language (Language 1, Language 2)
Temp Scale (°F, °C)
Buzzer Settings (End of Cycle, Beep Count)
Top Back Light (0-200)
Bottom Back Light (0-200)
Ready Prompt (To start insert #, Ready, Custom)
Machine Settings
Lint Cleaning Frequency (0-3 Hours)
Axial Max Temp (100° - 180° F / 38° - 82° C)
Burner Setup (One / Two) Not Available on Stack
Hi Key
Time for Amount to Start (1-99 Minutes)
Time for Top Off (1-99 Minutes)
Dry Temp (100° - 160° F / 38° - 71° C)
Cool Time (0-9 Minutes)
Reversing Mode (OFF / ON)
Med Key
Time for Amount to Start (1-99 Minutes)
Time for Top Off (1-99 Minutes)
Dry Temp (100° - 160° F / 38° - 71° C)
Cool Time (0-9 Minutes)
Reversing Mode (OFF / ON)
Low Key
Time for Amount to Start (1-99 Minutes)
Time for Top Off (1-99 Minutes)
Dry Temp (100° - 160° F / 38° - 71° C)
Cool Time (0-9 Minutes)
Reversing Mode (OFF / ON)
Vending Options
Currency Symbol (USD, Pound, Euro, Yen, Token,
No Symbol, No Symbol or Decimal)
Vending Mode (Accumulative Time, Accumulative Coin)
Vending Safeguard (Bad Coin Reset, Bad Coin Lockout)
Clear Escrow (0-99 Minutes)
Clear Coin Vault (No / Yes)
Left Coin Value (1-2500)
Right Coin Value (1-2500)
Amount to Start (1-2500)
Amount for Top Off (1-2500)
Debit Card Setup (Off, Gen 1, Gen 2)
Diagnostic Mode Fault Recording
Diagnostic Cycle
Help Mode
Machine Setup Note: this location is password protected (password is “MED” key four times).
Model
Gas non-reversing, electric non-reversing, steam non-reversing,
gas reversing, electric reversing, steam reversing
Dryer Type
Coin/Free
OPL
Factory Settings Note: this location is password protected
(contact factory if information is necessary)

KEY FUNCTIONS

LOW
Scroll down/decrease value
HIGH
Scroll up/increase value
MEDIUM
Accept selection
PAUSE / STOP
Back out of a location
Quick Reference Programming Menu for Coin/Debit/Free Models _________________