113604-4 www.amdry.com 9
!
Programming Selections ______________

MAIN MENU

When PROGRAM Mode is first entered, the control will enter
the PROGRAM Mode main menu. This main menu will serve
as the gateway to all of the PROGRAM Mode features. The
features include MACHINE INFO, PROGRAM SETUP,
DIAGNOSTIC MODE, MACHINE SETUP, and FACTORY
SETTINGS.
Note
If a fault occurs while in normal operation, and the
faults were not cleared, then these faults will be
displayed in the upper display when the SERVICE SWITCH
has been transitioned. Pressing the MED/ENTER key will
enable the user to enter into Service Mode.
The LOW/DOWN ARROW key will enable the user to scroll
through all the menu items.
Each menu in Service Mode will contain a list of selectable
items. The use of the HI/UP ARROW key and the LOW/DOWN
ARROW key on the keypad will enable the currently selected
item to change. The currently selected menu item will appear
with a box around it.
If the menu contains a list of items that will lead to a
sub-menu, then the items will be listed in ascending
numbered order starting at one. Once the item is selected
and entered, the controls will go to the sub-menu.
If the menu item does not lead to a sub-menu, the items will
only be listed and not numbered. When the item is selected
and entered, the selected item will become highlighted.
Some of these items without a sub-menu do contain
selectable parameters. These parameters will be viewed to
the right of the item. Once the item is highlighted, the
parameter can be changed.

1: MACHINE INFORMATION

Machine information will display the coin vault* upper/lower
hours**, SERIAL NUMBER, and the SOFTWARE REV. All of
the items on the MACHINE INFORMATION SCREEN will be
read only.
* Coin models only.
** Stack units will appear as upper and lower.
Actual listing will be as follows:
COIN VAULT: XX. XX Amount of coin accumulated since
last cleared. (Coin models only)
UPPER/LOWER
HOURS:
XX XX X X Total amount o f hours run.
SERIAL
NUMBER:
XXX XX X The 6 digit serial number entered
by the factory.
SOFTWARE
REV:
XXX The software revision loaded on
the control board.

2: PROGRAM SETUP

While the control is displaying “SERVICE MODE” and
PROGRAM SETUP is highlighted, press the MED/ENTER key
to enter this menu.
Note
All default settings are illustrated in underlined
bold italics.
1: CONTROL SETTINGS
1: LANGUAGE
1: MULTI LANGUAGE
ON / OFF
2: LANGUAGE 1 – allows the user to change the
language shown on the display.
ENGLISH
FRENCH
SPANISH
ITALIAN
DUTCH
JAPANESE
3: LANGUAGE 2 – allows the user to change the
second language on the display if multi language
is set to “ON”.
ENGLISH
FRENCH
SPANISH
ITALIAN
DUTCH
JAPANESE
2: TEMP SCALE – will display temperatures as
degrees Fahrenheit or Celsius.
° F / ° C
3: BUZZER SETTINGS
1. END OF CYCLE – controls audible beep
OFF / ON
2. BEEP COUNT – adjusts number of beeps
(duration) (adjustable between 1-10 beeps)
5
4: TOP BACKLIGHT – adjusts brightness of top
display.
0(adjustable from 0 to 200
0 = brightest and 200 = dimmest)
5: BOTTOM BACKLIGHT – adjusts brightness of
bottom display. (Not available on single [8.3]
computers.)
0(adjustable from 0 to 200
0 = brightest and 200 = dimmest)
6: READY PROMPT (used on coin/debit only)
1. Ready Prompt
To start insert
Ready
Custom (up to 21 characters)
2. Custom
(This will enable you to enter a custom
display)
!

SERVICE MODE

1: MACHINE INFO
2: PROGRAM SETUP
3: DIAGNOSTIC MODE
4: MACHINE SETUP
5: FACTORY SETTINGS