Panel Configuration Select Range: [01..41] [02..42]

Installation and Configuration

Configuration

Configure the branch current monitoring parameters using either the Panel configuration option or Global panel config option on the Panel screen of the PDU display interface.

Panel Config. Configure the branch metering settings for each circuit breaker on the distribution panel, or configure both panels simultaneously. To configure a circuit breaker, select the range that includes the circuit breaker. The top line of selections on the

screen applies to the top distribution circuit breaker panel on the PDU. The bottom line of selections applies to the bottom distribution circuit breaker panel on the PDU. The panel position numbers on the screen correspond to the numbers on the distribution panel. Odd numbers are on the left; even numbers are on the right. Once you have selected the correct range, configure the settings for each circuit breaker in the range.

Pos: The panel positions in the selected range.

Breaker: There are two configurable items:

The circuit breaker rating, in amps

The circuit breaker tie indicator: Define the number of tied panel positions (i.e., associated). You can associate panel positions with circuit breakers, to view the status about each circuit breaker and to receive alarm notification when any of a circuit breaker’s poles are above or below the configured branch circuit limit. You can also tie together panel positions that are logically associated. For example, you can tie together panel positions for three separate circuit breakers that are connected to the same PDU power cord and that provide power to the same equipment enclosure.

To configure the values on this screen:

1.From the first column, use the arrow keys to scroll up or down to the pole position you want to configure.

2.Press the ENTER key to move to the item you want to configure in the third column (the circuit breaker rating or the circuit breaker tie indicator).

3.Scroll again to select the value you want for the circuit breaker rating or the circuit breaker tie indicator. To associate one panel position with the next position in the list, choose the + character as the tie indicator immediately following the circuit breaker rating. To indicate that the position is not associated with (tied to) the next panel position in the list, choose the ] character as the tie indicator immediately following the circuit breaker rating. When you change the + or ] character that follows the circuit breaker rating in one row, the + or [ character before the circuit breaker rating in the next row also changes to indicate the changed association between the panel positions.

For example, this screen shows three, single-pole, 20A, tied

circuit breakers occupying positions 08, 10, and 12 on the

 

Pos

Breaker

 

08

[

20A

+

 

top right distribution panel.

10

+

20A

+

12

+ 20A ]

Branch Current Monitoring Kit

5

Page 5
Image 5
American Power Conversion PDU manual Configuration, Top right distribution panel

PDU specifications

American Power Conversion (APC), a subsidiary of Schneider Electric, is a renowned leader in providing high-performance power management solutions. One of their standout offerings is the Power Distribution Unit (PDU), a critical component for data centers and network operations. The PDU is designed to distribute and manage electrical power efficiently, ensuring the continuous operation of IT equipment and infrastructure.

One of the key features of APC PDUs is their versatility. They come in various configurations, including basic, metered, and monitored models, allowing users to select the right unit according to their specific needs. The basic PDUs provide essential power distribution, while metered and monitored versions offer additional features for tracking power usage. This flexibility ensures effective data center management, accommodating different scales of operations from small server rooms to large enterprise environments.

APC PDUs are equipped with advanced technologies that enhance power efficiency and reliability. Many models feature intelligent monitoring capabilities, allowing remote access and real-time status updates. This functionality enables IT administrators to monitor their power usage and environmental conditions from anywhere, ensuring optimal performance and reducing downtime risks. Additionally, many PDUs are compatible with Schneider Electric's EcoStruxure IT platform, providing enhanced analytics and insights that foster smarter decision-making.

APC PDUs also incorporate safety mechanisms to protect valuable equipment. Features like surge protection, circuit breakers, and overload alerts are standard in many models, ensuring that connected devices are safeguarded from electrical anomalies. This focus on resilience is vital for maintaining the integrity of mission-critical operations across various sectors.

The construction of APC PDUs reflects a commitment to robustness and longevity. They are built using high-quality materials designed to withstand harsh data center conditions. Many units feature rack-mount designs, optimized for maximizing space and facilitating easy installation. Their user-friendly design simplifies the setup process, allowing IT personnel to quickly deploy and disseminate power throughout the facility.

Furthermore, APC's commitment to sustainability is evident in their design philosophy. Many PDUs are engineered to optimize energy consumption, helping businesses reduce their carbon footprint while lowering operational costs. This aligns with the increasing emphasis on green initiatives in technology infrastructure.

In summary, APC PDUs represent a blend of versatility, advanced technology, and robust design, making them a cornerstone for effective power management in modern data centers. With intelligent monitoring, safety features, and a focus on sustainability, APC PDUs not only enhance operational efficiency but also contribute to the strategic goals of businesses navigating the ever-evolving technological landscape.