Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual 3
Introduction

About this UPS

The American Power Conversion (APC®) Uninterruptible Power Supply (UPS) provides protection for
electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility
line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from
utility line power. The UPS provides continuous power from the internal battery until utility power returns to
safe levels or the battery is fully discharged.

Unpack

Read the Safety Guide before installing the UPS.
Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage.
The packaging is recyclable; save it for reuse or dispose of it properly.
Check the package contents:
Specifications
NOTE: The model and serial numbers are located on a small, rear panel label. For some models, an additional label
is located on the chassis under the front bezel.
•UPS
•Front bezel
•Literature kit containing:
EPO connector
Serial cable
USB cable
Eight ornamental screws for
securing the unit in the rack
Eight 5/16 in (.8 cm) pan-head
screws for attaching cleats to the
chassis rails
(required for four post rack only)
Eight 5/8 in (1.6 cm) pan-head
screws for attaching rack-mount
brackets to the unit
Eight snap-on speed nuts
Two rail cleats (required for four post
rack only)
Two rack-mount brackets
Product documentation
Smart-UPS® User Manuals CD
PowerChute® Business Edition CD
Safety information
Warranty information
Additional contents for
230 V models:
APC power cable
Alternate input power cord
(UK customers)
–IEC Power cord
IEC jumper cables
Temperature
Operating
Storage
32° to 104° F (0° to 40° C)
5° to 86° F (-15° to 30° C) charge the UPS battery every six months
86° to 113° F (30° to 45° C) charge the UPS battery every three months
This unit is intended for indoor use
only. Select a location sturdy enough
to handle the weight.
Do not operate the UPS where there
is excessive dust or the temperature
or humidity are outside the specified
limits.
Environmental factors impact battery
life. High temperatures, poor utility
power, and frequent, short duration
discharges will shorten battery life.
Maximum
Elevation
Operating
Storage 10,000 ft (3,000 m)
50,000 ft (15,240 m)
Humidity 0 to 95% relative humidity, non-condensing
Weight 142 lbs (64 kg) with battery module
89 lbs (40 kg) without battery module
27 lbs (12 kg) each battery module
142 lbs (64 kg)
Maximum Number of External Battery Packs Supported by the
Smart-UPS XL
10