Image 1
DO NOT OVERTIGHTEN NUTS

ChinaLux 1000 EL INSTALLATION INSTRUCTIONS ChinaLux 1000 RF CARE AND MAINTENANCE

To ensure this product is installed properly, please read these instructions carefully before you begin.

Certain installations may require professional help.) Also be sure your installation conforms to local codes.

!CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!

NOTE: Pictures may not exactly define contour of china and components.

RECOMMENDED TOOLS AND MATERIALS

Putty Knife

Regular Screwdriver

Adjustable Wrench

Wax Ring/Gasket

Flexible Supply Tube

Tape Measure

Closet Bolts

Hacksaw

Sealant

Carpenters Level

Seat

 

1REMOVE OLD TOILET

a.Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.

b.Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!

c.Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.

d.Remove closet bolts from flange and clean away old wax, putty, etc. from base area. NOTE: Mounting surface must be clean and level before new toilet is installed!

2 ROUGHING-IN DIMENSIONS:

3 INSTALL CLOSET BOLTS

 

 

NOTE: Distance from wall to closet flange centerline

 

Install closet bolts in flange channel, turn 90°, and slide into

 

must be as listed below:

 

place 6" (152 mm) apart and parallel to wall.

 

 

For 120012 Tanks: Rough-in distance is 305mm (12")

 

 

 

4

INSTALL WAX SEAL

5

POSITION TOILET ON FLANGE

BOLT

 

 

CAP

 

 

 

 

NUT

 

Invert toilet on floor (cushion to prevent damage),

 

a. Unplug floor waste opening and install toilet on

TAPERED

 

 

WASHER

 

and install wax ring evenly around waste flange

 

closet flange so bolts project through

 

 

(horn), with tapered end of ring facing toilet. Apply

 

mounting holes.

 

 

a thin bead of sealant around base flange.

 

b. Loosely install retainer washers and nuts. Side of

 

 

 

 

washers marked “THIS SIDE UP” must face up!

CLOSET

 

 

 

 

BOLT

6

INSTALL TOILET

7

INSTALL TANK

 

 

 

RUBBER

 

 

 

WASHER

 

a. Position toilet squarely to wall and, with a rocking

 

a. Install large rubber gasket over threaded

 

 

 

motion, press bowl down fully on wax ring and flange.

 

outlet on bottom of tank and lower tank

TANK MTG.

RUBBER

 

Alternately tighten nuts until toilet is firmly seated

 

onto bowl so that tapered end of gasket

BOLTS

GASKET

 

 

 

 

on floor.

CAUTION:

 

fits evenly into bowl water inlet opening.

 

 

 

!

 

b. Insert tank mounting bolts and rubber

 

 

 

DO NOT OVERTIGHTEN NUTS

 

washers from inside tank, through

 

 

 

 

OR BASE MAY BE DAMAGED!

 

mounting holes and gasket, and secure

 

 

 

b. Install caps on washers. (If necessary, cut bolt height

 

with metal washers and nuts.

 

 

WASHER

 

 

 

c. With tank parallel to wall, alternately

NUT

 

 

to size before installing caps.)

 

tighten nuts until tank is

 

 

 

 

 

c. Smooth off the bead of sealant around base.

 

snugged down evenly

!

CAUTION:

 

 

 

Remove excess sealant.

 

against bowl surface.

 

DO NOT OVERTIGHTEN NUTS MORE

 

 

 

 

 

 

THAN REQUIRED FOR A SNUG FIT!

8 INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer’s directions.

S A V E F O R F U T U R E U S E

9CONNECT WATER SUPPLY

TANK

WATER INLET

10 ADJUSTMENTS

 

FLOW RATE

TO RAISE

ADJUSTMENT

a. Flush tank and check that

WATER

 

LEVEL

OVERFLOW LIFT

 

 

ROD

a. Connect water supply line between shutoff valve and tank water inlet fitting. Tighten COUPLING NUT 1/4 turn beyond hand tight. Check that refill tube is inserted into overflow tube.

b. Turn on supply valve and allow tank to fill until float rises to shutoff position.

c. Check for leakage at fittings, tighten or correct as needed.

d. Do not use plumber's putty to seal these fittings.

WASHER OR BASE MAY BE DAMAGED!S A V E F O R F U T U R E U S E

COUPLING NUT

FLEXIBLE

SUPPLY

 

Manual background VALVE NUT

Manual backgroundManual background COMPRESSION

COLLAR

TRIM PLATE

VALVE

CAUTION: Overtightening of COUPLING NUT could result in breakage and potential flooding.

tank fills and shuts off within

 

TO LOWER

+

REFILL

TUBE

30 to 60 seconds, and tank

 

WATER

-

 

 

LEVEL

 

TUBE

 

water level is set as

 

TRIP

C L

 

FIG. 10A

specified on tank rear wall.

 

LEVER

 

 

FLOAT

WATER

 

 

BALL

b. To adjust water level:

 

 

CONTROL

 

 

 

turn water level adjustment

ASSEMBLY

 

 

 

screw counterclockwise to

WATER

 

 

 

 

LINE

 

 

 

raise level; turn adjustment

 

LEVEL

 

 

 

 

WATER

 

 

FLAPPER

screw clockwise to lower level.

 

 

INLET

 

FLUSH

ASSEMBLY

c. To adjust flow rate (tank fill time):

 

 

 

VALVE

 

turn flow rate adjustment screw

clockwise to decrease flow rate (increase fill time); turn adjustment screw counterclockwise to increase flow rate (decrease fill time).

d. Carefully position tank cover on tank.

e. The flush valve float has been factory set and does not require adjustments. Repositioning of the float will change the amount of water used which may effect the toilet's performance.

f. If bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the chain from the retainment clip (see Fig. 10) and take up slack on the chain, and reinsert on lift rod. Make sure the chain is not too taught.

7301311-100 Rev.A

Page 1
Image 1