11 INSTALL HANDLES

 

 

Push ADAPTER (1) on VALVE STEM (2), so that the hole of the

 

 

ADAPTER (1) without a spline is facing up. See figure "A". Tighten

 

THREAD ON

STEM SCREW (3) to secure ADAPTER (1).

4

TO DECK

Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting

ADAPTER

 

 

male teeth on ADAPTER (1) to female teeth in HANDLE (4).

TOP

 

Thread LEVER HANDLE ASSEMBLY (4) onto ESCUTCHEON (5)

 

1

until snug against mounting surface.

 

3

Figure "A"

 

 

 

2

SPLINE END DOWN

 

5

12 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.

Operate both HANDLES (1) to flush water

1

lines thoroughly.

 

Rotate TRANSFER VALVE (5) from rim wash to

 

spray several times to check operation.

 

OUTLINE OF BIDET

3

1

13 CHECK DRAIN CONNECTIONS

Pull up POP-UP KNOB (3) and fill Bidet with water. Check

that DRAIN STOPPER (4) makes a good seal and retains4 water in Bidet. If STOPPER (4) does not seal properly,

please refer to “Troubleshooting Guide” in these instructions.

Push POP-UP KNOB (3) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

2

2

SPRAY

14 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

15

SERVICE

 

 

 

 

To change direction of handle rotation,

 

 

 

 

 

 

 

 

 

proceed as follows:

UNTHREAD

 

 

 

 

Turn valve to OFF position.

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thread counter-clock wise HANDLE BASE (1) to remove

 

 

 

 

 

 

 

 

 

 

 

 

 

HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).

 

 

 

 

 

Use a flat blade screw driver to remove SPRING CLIP (4).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lift STOP WASHER (5), turn 90˚

and replace.

5

 

 

 

 

 

 

 

 

 

 

 

 

Replace SPRING CLIP (4).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reinstall HANDLE ASSEMBLY (2).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If spout drips, operate handles several times from OFF 3 to ON position. Do not force - handles turn only 90˚.

2

VALVE

90˚

4

M968924 Rev.1.3

Page 4
Image 4
American Standard 2064.4 installation instructions Install Handles, Test Installed Fitting, Check Drain Connections