American Standard 2175.503 Test Installed Fitting, Check Drain Connections, Service

Models: 2175.503

1 6
Download 6 pages 33.88 Kb
Page 4
Image 4
9 TEST INSTALLED FITTING

9 TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks. 10 CHECK DRAIN CONNECTIONS

Ensure that AERATOR (3) is tightened completely.

Operate HANDLE (1) to to alow water flow.

10 CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks. 11 SERVICE

Tighten if necessary.

5 1

3

4

WASTE

OUTLET

Manual background2

2

“P” TRAP

11 SERVICE

1

If Faucet Drips Proceed As Follows:

Turn VALVE in OFF position.

If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE INLETS may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:

2

4

Remove HANDLE (1), CAP (2) and CARTRIDGE (3).

Clean CARTRIDGE INLETS and MANIFOLD.

Reassemble CARTRIDGE (3), alternately tightening SCREWS (4). Replace CAP (2) and HANDLE (1). Check flow.

3

CARTRIDGE INLETS Manual background

MANIFOLD

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968882 Rev. 1 . 3

4

Page 4
Image 4