Installation
Instructions
TOWNSQUARE2555.602
PRESSURE BALANCING BATH AND
with EverClean™ Finish
Congratulations on purchasing your American Standard faucet with EverClean finish found only on American Standard faucets.
EverClean Finish
•One wipe effortlessly removes spots
•Eliminates the need for cleaners and scrubbing
•Permanent surface protectant remains beautiful for the life of the faucet
•EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
Certified to comply with ANSI A112.18.1
M968789 Rev. 1 . 2
To ensure that your installation proceeds
Required Tools
Phillips Screwdriver
Flat Blade Screwdriver
Plumbers' Putty or Caulking
Channel Locks
Adjustable Wrench
To assure proper positioning in relation to wall, note
FINISHED WALL |
| |||
|
|
| ||
| 1 | 1/2" I.P.S. |
| |
|
|
| ||
2" REF. |
| OPTIONAL TO |
| |
|
|
| ||
|
| FINISHED FLOOR |
| |
|
| USUALLY BETWEEN |
| |
|
| 65'' AND 78'' |
| |
| 8" REF. |
|
| OUTLETS 1/2" NPT |
74" FOR |
|
|
|
|
HEAD CLEARANCE |
|
|
|
|
|
| SHW | "SEE ILLUSTRATION" |
|
| ||||
|
|
| ||
|
| TUB |
|
|
18" |
|
|
|
|
OPTIONAL |
|
|
| |
|
| |||
|
|
| ||
|
| 1/2" NPT | INLETS | |
|
| 1/2" NPT | THREADED INLETS (STOPS) | |
TOP OF | 4" | 1 |
| |
TUB RIM |
|
|
|
|
BOTTOM OF |
|
|
| |
TUB |
|
|
|
|
1 |
|
| |
CAUTION | Turn off water at main supply. | ||
|
|
| |
|
|
|
|
NOTE When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering, flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread sealant or Teflon tape on threaded connections.
5
7
See
1/2" female NPT for threaded inlets Connect RISER PIPE (1) to MANIFOLD (2) top outlet marked "SHR".
Connect TUB FILLER PIPE (3) at bottom outlet marked "TUB".
For proper positioning the finished wall must be within side wall of PLASTER GUARD (4).
If the valve is installed on a fiberglass | 1 | |
or other thin wall application, the | 2 | |
PLASTER GUARD (4) can be used as a support. | ||
| Cut a 4" dia. hole in the shower stall. |
|
|
| |
|
| |
| Drill two additional 1" holes to allow access |
|
|
| |
|
| |
| to the stops. | HOT |
| Remove PLASTER GUARD (4), rotate 180˚ |
|
|
| |
|
| |
| so that indicated screw holes fit MANIFOLD (2). |
|
| Push CAP on valve, place ESCUTCHEON on and | 3 |
| ||
| ||
| attach with screws. |
Connect hot and cold water supplies.
Cap off shower pipe (5) and tub filler pipe (6).
For support, use pipe BRACES (7) secured to wooden braces. With valve turned off, turn on water supplies. Check for leaks.
COLD 4
6