CADET™ CORNER
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
2775.XXXW SERIES WHIRLPOOL
INSTALLATION INSTRUCTIONS
165mm
RECOMMENDED FITTING LOCATION
64 X 330mm
OUTLINE OF
CUTOUTC/L
1080 mm
2159mm
(85)
1080mm | 229 X 305mm |
| |
(9 X 12) |
| ||
CUTOUT IN |
| ||
| FLOOR FOR |
| |
| DRAIN | 1076mm | |
|
| ||
| |||
|
|
| |
| HEATER | 1524mm | |
| REMOVABLE | ||
| BLANK |
| (60) |
70mm REF. | ON/OFF |
| |
SWITCH |
| ||
|
| PROVIDE ACCESS | |
|
| TO PUMP FOR | |
|
| SERVICING ON ALL | |
| PUMP | INSTALLATIONS |
279mm
(11)
C/L OF
DRAIN OUTLET
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
•
•Tile Bead Kit
* see your American Standard Dirstributor
| C/L OF | 76mm | LEVELING STRINGER | |
| (3) | NOT FOR SUPPORT | ||
38 mm REF. | OVERFLOW |
|
| |
|
|
| ||
|
|
|
| |
|
|
|
| 502mm |
|
|
|
| |
INTEGRAL |
|
|
| 464mm |
|
|
| ||
SUPPORT |
|
|
| |
|
|
|
| |
FEET |
|
|
|
|
ROUGH |
|
|
| |
FLOOR | THREADS |
|
| 117mm |
|
|
| 70mm | |
|
| |||
|
| |||
|
|
|
|
List of Required Components (not included):
• Drain* 1583.470 | • Bath Filler* |
* see your American | Standard Dirstributor |
GENERAL SPECIFICATIONS FOR 2775 WHIRLPOOL
INSTALLED SIZE |
|
|
|
|
| 85 X 60 X | |||||||||||||||
|
|
|
| ||||||||||||||||||
WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 130 Lbs. (59 Kg.) | ||||||
WEIGHT w/WATER |
|
|
|
|
|
|
|
|
| 756 Lbs. (343 Kg.) | |||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||
GAL. TO OVERFLOW |
|
|
|
|
|
|
|
|
|
|
|
| 75 Gal. (284 L.) | ||||||||
MIN. OPERATING GAL. |
|
|
|
|
|
|
|
|
|
|
| 60 Gal. (227 L.) | |||||||||
BATHING WELL AT SUMP |
|
| 32 X 32 In. (813 mm X 813 mm) | ||||||||||||||||||
BATHING WELL AT RIM |
|
|
|
|
|
| 46 X 46 In. (1168 X 1168mm) | ||||||||||||||
|
|
|
|
|
| ||||||||||||||||
WATER DEPTH TO OVERFLOW |
|
|
|
|
|
|
| 14 In. (356 mm) | |||||||||||||
|
|
|
|
|
| ||||||||||||||||
FLOOR LOADING |
|
|
|
|
|
| 34 Lbs./Sq. Ft. (115 Kgs/Sq. m.) | ||||||||||||||
|
|
|
|
|
| ||||||||||||||||
(PROJECTED AREA) |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
PTS. |
|
|
|
|
|
| 41.7 | ||||||||||||||
CUBE | (FT3) |
|
|
|
|
|
| 70.4 |
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP |
| 2.1 HP, 14.4 AMPS, 120V. |
|
GENERAL INSTALLATION INFORMATION
List of Required Tools and Supplies:
Tools | Supplies | ||
• | Level | • | Nails |
• | Tape Measure | • | Putty |
• | Pipe Wrench | • | Caulking (waterproof) |
• | Slip Joint Pliers | • | 1 x 3 or 2 x 2 |
• | Screw Driver |
| Stringers |
• | Standard | • | Drop Cloth |
| Woodworking Tools | • | 20 amp GFI |
• | Personal Safety |
| Outlet |
| Equipment | • | Cement, Plaster, |
• | Caulking Gun |
| Grout |
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© American Standard Inc. 2003