American Standard 3875-403 Test Installed Fitting, Check Drain Connections, Cold, 13SERVICE

Models: 3875-503 3875-403

1 6
Download 6 pages 18.45 Kb
Page 4
Image 4
2

9

INSTALL HANDLE TRIM

4

5

 

 

LEVER HANDLE

4

Turn HANDLE STEM (1) to "OFF" position.

 

Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the

3

ADAPTER SCREW (3) and tighten securely.

5

 

Position LEVER HANDLE (4) and place on ADAPTER (2). Install the

HANDLE SCREW (5) and tighten securely.

3

ACRYLIC HANDLE

Turn HANDLE STEM (1) to "OFF" position.

Place the HANDLE ADAPTER (2) on the HANDLE STEM (1).

Position ACRYLIC HANDLE (3) and install on ADAPTER (2). Install the HANDLE SCREW (4) and tighten securely.

Push in INDEX BUTTON (5). (Hot-left side, Cold-Right side)

2

2

11

10 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.10 TEST INSTALLED FITTING

Remove AERATOR (3).

 

Operate both HANDLES (1) to flush water

1

lines thoroughly.

Replace AERATOR (3).

11 CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks.11 CHECK DRAIN CONNECTIONS Tighten

if necessary.

1

15

3 COLD

4

WASTE

OUTLET

2

COLD

“P” TRAP

2

HOT

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES,

13 SERVICE

To change direction of handle rotation, proceed as follows:

Turn VALVE to OFF position.

Loosen HANDLE SCREW (1) .

Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER SCREW (4) and pull off ADAPTER (3).

Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches on the other FLAT on VALVE STEM (5).

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).

113 SERVICEHARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

2

4

3

HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

Tighten HANDLE SCREW (1).

5

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

M968886

4

Page 4
Image 4
American Standard 3875-403, 3875-503 Test Installed Fitting, Check Drain Connections, Cold, 13SERVICE