American Standard 6028.240 Install Handles, 10a TEST INSTALLED FITTING, Check Drain Connections

Models: 6028.240

1 6
Download 6 pages 20.21 Kb
Page 4
Image 4
10 INSTALL HANDLES

10 INSTALL HANDLES

 

5

 

Turn VALVE into OFF position.

4

8

Push ADAPTER (1) into VALVE STEM (2).

 

 

 

Align HANDLE (3) and install onto ADAPTER (1).

3

 

Install HANDLE SCREW (4) and tighten to secure

 

 

 

HANDLE (3).

 

 

Insert INDEX BUTTON (5).

 

 

 

1

 

10a TEST INSTALLED FITTING

 

2

 

7

 

 

With HANDLES (3) in OFF position, turn on WATER SUPPLIES (6) and check all connections for leaks.

Remove AERATOR (7).

Operate both HANDLES (3) to flush water lines thoroughly.

Replace AERATOR (7).

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (8) and fill lavatory with water. Check that DRAIN STOPPER (9) makes a good seal and retains water in SINK. If DRAIN STOPPER (9) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (8) down and check all drain connections and "P" trap for leaks. Tighten

9

WASTE

OUTLET

if necessary.

6

6

“P” TRAP

11 SERVICE

To change direction of handle rotation, proceed as follows: 10a TEST INSTALLED FITTING Turn valve to OFF position.

CHECK DRAIN CONNECTIONS Pull out INDEX CAP (1) and remove HANDLE SCREW (2). 6 11 SERVICE Pull off HANDLE (3) and ADAPTER (4).

90˚

1

2

3

12 CARE INSTRUCTIONS: Remove SPRING CLIP (5).

Lift STOP WASHER (6), turn 90˚ and replace. Manual background Replace SPRING CLIP (5).

Replace ADAPTER (4), HANDLE (3), SCREW (2), and INDEX CAP (1).

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

5

4

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968491 Rev . 1 . 2

4

Page 4
Image 4
American Standard 6028.240 Install Handles, 10a TEST INSTALLED FITTING, Check Drain Connections, Service