3HOW TO SET DEFAULT TEMPERATURE Fig. 3

Note: The factory setting of the Default Temperature is at a position of even amounts of hot and cold water flows. This setting can only be changed within the first 15 minutes of switching on the power.

1.Remove the power to the faucet by unplugging the Power Supply from the wall outlet. Wait 60 seconds, and then plug the Power Supply Back into the wall outlet.

2 . Place hand in front of Blue (Cold) Sensor until the Blue LED lights up. Fig. 3.

Fig..23

 

Fig. 3a

ADJUST HOT

 

 

ADJUST

 

RED SENSOR

COLD

 

BLUE

 

 

SENSOR

 

3. Within the next 5 seconds, start the faucet water flow

by placing hand within the On/Off Sensor range. Fig. 3.

4. Adjust the output faucet temperature by using the

Red (Hot) Sensor to increase, or Blue (Cold) Sensor to

decrease. During this process always keep your hand

within The On/Off Sensor range in order to feel the

change water temperature. Fig. 3, Fig. 3a.

5. Once desired temperature has been set, remove

hands away from the range of sensors. Water flow will

stop and both Red and Blue sensors will light-up for 2

seconds indicating the default temperature has been set.

6. The Default Temperature has been set. This will

remain the default setting untill the setting is changed

Fig. 1

1

Fig. 1a

3

24

5

6

again. If power is lost, this will remain the default

setting.

Note: The Default Setting is actually a mechanical positioning of a mixing valve. Changes in the supply temperatures will create changes to the Default Temperature.

MAINTENANCE

1HOW TO REMOVE MIXING VALVE Fig. 1

1.Remove four screws and pull off ENCLOUSURE COVER (1). Fig. 1.

2.Remove MOTOR GEAR COVER (2) by pulling off or pry off with a flat-blade screw driver. Fig. 1a.

3.Remove SCREW (3) from the center of the LARGE GEAR (4) and two SCREWS (5) from the MOTOR HOUSING (6). Fig. 1a.

4.Pull of MOTOR HOUSING (6) with LARGE GEAR

(4) from the MIXING VALVE STEM (7). Fig. 1b.

5.Remove LOCKNUT (8) from the MIXING VALVE HOUSING (9) using adjustable wrench. Fig. 1c.

6.Pull out MIXING VALVE (10). Use pliers if necessary.

Fig. 1d.

7.Reverse above steps for assembly.

Fig. 1b

6

7

Fig. 1c

INSTALL

REMOVE

8

9

Fig. 1d

10

6

M968857 REV. 1. 2

Page 7
Image 7