OPERATION

1HANDWASH SENSOR OPERATION; Fig. 1

When the Sensor detects a user, the water immediately starts to flow. Water flow will stop Two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for 59 seconds. The water will stay off until the blockage is removed from the detection zone.

Output water temperature has a default setting. See Section 3 for “How to Set Default Temperature.” To change the output water temperature place one hand within the On/Off Sensor range to activate faucet, then place other hand within the Blue Sensor to decrease water temperature, or the Red Sensor to increase water temperature. Blue or Red LED will light up when hand is within the sensor range. The Blue and Red sensor ranges cannot be adjusted.

Note: If On/Off Sensor is not activated within 15 seconds of temperature adjustment, then the faucet will adjust back to the default temperature settings.

Detection Zone: 2" - 10" (50mm - 250mm)

Default: Set at Factory 6" (150mm)

2HOW TO CHANGE ON/OFF SENSOR RANGE; (Factory set at 6") Fig. 2a, 2b

1.Setting the Detection Zone (Distance):

Remove cover from ENCLOSURE. Disconnect GRAY SENSOR WIRE (1) from circuit board, then reconnect.

Fig. 2.

2.While the SENSOR CONTROL LED (2) is blinking slowly, place your hand 1 - 2 in. (30-50mm) in front of the sensor. Fig. 2a.

3.When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. 2b.

4.Once the SENSOR CONTROL LED (2) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.

5.Replace cover on ENCLOSURE.

Fig. 1

BLUE

REDSENSOR

SENSOR

 

DETECTION

 

 

ZONE

2"

-10

" (50mm

-250mm)

 

 

 

 

 

 

ON/OFF SENSOR

Fig. 2

. 2

1

Fig. 2a

1" - 2" (30mm - 50mm)

2BLINKING LED

Fig. 2b

UP TO 10" (250mm)

2 BLINKING LED

5

M968857 REV. 1. 2

Page 6
Image 6
American Standard 6058.105 Handwash Sensor Operation Fig, HOW to Change ON/OFF Sensor Range Factory set at 6 a, 2b