10 TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3). | 4 |
Operate both HANDLES (1) to flush water lines thoroughly.
1
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate
Release
if necessary.
1
3
5
WASTE
OUTLET
2
2 | “P” TRAP |
11 SERVICE
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position. |
|
Remove IINDEX (1) and HANDLE SCREW (2). |
|
Pull HANDLE (3) off. |
|
Remove ADAPTER (4) and SPRING CLIP (5). |
|
Lift STOP WASHER (6), turn 90˚ and replace. |
|
Replace SPRING CLIP (5). | 90˚ |
Replace ADAPTER (4), HANDLE (2), SCREW (2), |
|
and INDEX (1). |
|
4
5
1
2
3
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
6
12 EverClean™ Finish Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
US60402 Rev. 1 . 1
4