American Standard T028.990 EverClean Finish Care Instructions, Install Hand Shower

Models: T028.990

1 2
Download 2 pages 22.14 Kb
Page 2
Image 2
3 INSTALL HAND SHOWER

3 INSTALL HAND SHOWER

Unscrew the HOLDER (1) from the SHOWER ESCUTCHEON (2). Slip the SHOWER HOSE (3) through the SHOWER ESCUTCHEON (2) and the HOLDER

(1).

Pull out the SLEEVE GUARD (6) and HOSE (7). Unthread the SLEEVE GUARD

13

(6) from the HOSE END (8) connection. Be careful not to allow the HOSE

 

(7) to fall back through the SLEEVE (9).

5

Insert SEAL WASHER (10) into the SHOWER HOSE CONNECTOR (11).

4

 

Thread the SHOWER HOSE CONNECTOR (11) onto the HOSE END (8) and

1

tighten securely.

 

Thread the SHOWER ESCUTCHEON (2) into the SLEEVE (9) until the

2

 

SHOWER ESCUTCHEON (2) contacts the finished deck.

 

Loosen the SET SCREW (12) in the SHOWER ESCUTCHEON (2) and rotate

3

 

the ESCUTCHEON (2) so that SET SCREW (12) faces the center of the tub.

 

Retighten the SET SCREW (12).

13

Thread the HOLDER (1) into the SHOWER ESCUTCHEON (2).

Insert a SEAL WASHER (4) into the SHOWER HOSE CONNECTOR (5)

 

and hand tighten HAND SHOWER (13) into

 

 

 

SHOWER HOSE CONNECTOR (5).

 

 

 

Place the HAND SHOWER (13)

 

 

1

into the HOLDER (1).

6

11

 

10

 

 

 

 

12

8

(7) to fall back through the SLEEVE (9).4 TEST INSTALLED DIVERTER5 EverClean™ Finish Care Instructions 2 7Manual background

9

4 TEST INSTALLED DIVERTER

Turn DIVERTER VALVE (1) fully clockwise (Tub fill position).

Turn on control valves and check all connections for leaks. With

DIVERTER VALVE (1) in clockwise position, flow should only come2 from tub spout.

Lift HANDSHOWER (2) from holder, direct spray into tub, turn DIVERTER VALVE (1) fully counter-clockwise to check HANDSHOWER (2) and HOSES (3) for leaks. With DIVERTER VALVE (1) in counter-clockwise position, flow should only come from HANDSHOWER (2).

Turn control valves "off."

1

3

5 EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

M968499 Rev. 1 . 1

Page 2
Image 2
American Standard T028.990 EverClean Finish Care Instructions, Install Hand Shower, to fall back through the SLEEVE