SEQUENCE OF INSTALLATIONS

Cut a length of PVC pipe about 3.5 in. (9cm) longer than the wall thickness at the opening. Glue the vent terminal to this section of pipe. Slide the wall plate over the pipe to stop against the vent terminal. Place a bead of caulking (not supplied) around the gap between the pipe and cover plate. Apply enough to fill some of the gap between the pipe and wall. Place some of the caulking on the back of the plate to hold it against the wall after installation. If the vent pipe is installed up to the wall, with a coupling on the end against the wall opening, the pipe with the vent terminal can be prepared for gluing before inserting through the wall. Slide the pipe through the wall and insert into the coupling on the other side of the wall, making sure that the vent terminal ends up pointed in the correct position (see Figure 23).

FIGURE 23

INSTALLATION SEQUENCE

For installations in the City of Los Angeles, California Category IV PVC Pipe such as that manufactured by Brownline Pipe Company, must be used as vent pipe material.

CAUTION

Vent terminals supplied with heater must be used.

NOTE: BEFORE BEGINNING INSTALLATION OF ANY VENT PIPE READ THE VENT PIPE MANUFACTURER’S INSTALLATION INSTRUCTIONS.

1.After the points of termination have been determined, use the cover plates as templates to mark the holes for the vent pipes to be inserted through the wall. BEWARE OF CONCEALED WIRING AND PIPING INSIDE OF WALL. If the vent terminals are being installed on the outside of a finished wall, it may be easier to mark both the inside and outside wall. Align the holes by drilling a hole through the center of the template from the inside through to the outside. The template can now be positioned on the outside wall using the drilled holes as a centering point for the template.

A.MASONRY SIDE WALLS Chisel an opening approximately 1/2 in. (1.3cm) larger than the marked circle.

B. WOODEN SIDE WALLS Drill a pilot hole approximately 1/4 in. (0.64cm) outside of the marked circle. This pilot hole is used as a starting point for a saws-all or sabre saw blade. Cut around the marked circle staying approximately 1/4 in (0.64cm) outside of the line. (This will allow the vent pipe to easily slide through the opening. The resulting gap will be covered by the vent terminal cover plates.) Repeat this step on the inside wall if necessary.

2.Cut a length of 3 in. PVC pipe about 3.5 in. (9cm) longer than the wall thickness at the opening.

3.Glue the intake vent terminal to the section of the pipe.

4.Slide the wall plate over pipe to stop against intake vent terminal.

5.Place a bead of caulking (not supplied) around the gap between the pipe and the wall. Place some of the caulking on the back of the plate to hold it against the wall after installation.

6.If the vent pipe is installed up to the wall, with a coupling on the end against the wall opening, the pipe with the vent terminal can be prepared for gluing before inserting through the wall. Slide the pipe through the wall and insert into coupling on the other side of the wall, making sure that the vent terminal ends up pointed in the correct position (see Figure 24).

FIGURE 24

26

www.americanwaterheater.com

Page 26
Image 26
American Water Heater 316888-004 warranty Sequence of Installations, Installation Sequence

316888-004 specifications

The American Water Heater 316888-004 is a reliable and efficient choice for homeowners seeking a dependable and effective water heating solution. Designed with a focus on performance and convenience, this water heater provides an impressive array of features that meet the demands of modern living.

One of the standout characteristics of the 316888-004 is its efficient heating technology. The unit employs advanced heating elements that ensure rapid heating of water, reducing wait times for hot water availability. This feature is particularly beneficial for households with high hot water demands, such as those with multiple bathrooms or numerous appliances requiring hot water simultaneously. By delivering hot water quickly, this model enhances user satisfaction and improves overall household efficiency.

In terms of design, the American Water Heater 316888-004 boasts a compact structure, which makes it suitable for various installation environments, including tight spaces. Its durable construction is complemented by high-quality materials, ensuring longevity and reduced maintenance costs. This model is built to withstand the rigors of daily use, providing peace of mind to homeowners regarding its reliability and durability.

Safety is another important aspect of the 316888-004. The unit is equipped with multiple safety features, including a temperature and pressure relief valve, which helps prevent overheating and excessive pressure buildup. Additionally, it accommodates users' needs for energy efficiency, making it an environmentally friendly option. The device is designed to minimize energy consumption, which not only lowers utility bills but also contributes to reducing the household's overall carbon footprint.

Moreover, the 316888-004 is user-friendly, featuring a simple control interface that makes adjusting temperature settings easy. This accessibility allows users to customize their water heating experience according to their personal preferences.

In conclusion, the American Water Heater 316888-004 stands out as a top choice in its category. With its efficient heating technology, durable construction, focus on safety, energy efficiency, and user-friendly features, it meets the diverse needs of contemporary households. For anyone seeking a reliable, high-performance water heater, the 316888-004 is undoubtedly a smart investment, ensuring consistent hot water availability for years to come.