Important: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of the water, the tank will eventually leak after an extended period of time. Also any external plumbing leak, including those from improper installation, may cause early failure of the tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair a qualified service technician should be contacted. A suitable metal drain pan should be installed under the water heater as shown below, to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank. The pan must limit the water level to a maximum depth of 1-3/4” and be two inches wider than the heater and piped to an adequate drain. The pan must not restrict combustion air flow. Locate the water heater near a suitable indoor drain. Outside drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4” ID and pitched for proper drainage. Under no circumstances will the manufacturer or seller of this water heater be held liable for any water damage which is caused by your failure to follow these instructions.

1 3/4” Max

Pipe to

Adequate

Drain

At least 2” inches greater than the diameter of the water heater.

·The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the data plate.

Clearances and Accessibility

Notice: Minimum clearances from combustible materials are stated on the data plate adjacent to the thermostat of the water heater.

·The water heater is certified for installation on a combustible floor.

Important: If installing over carpeting, the carpeting must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least 3 inches (76.2mm) in any direction or if in a alcove or closet installation, the entire floor must be covered by the panel. The panel must be strong enough to carry the weight of the heater when full of water.

Figure 2 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection and service.

Figure 2: Minimun Clearance Locations

Vent 0”

Back 0” Sides 0”

Front

4” Inches Sides

From 0”

Combustibles

Top

View

Vent Cap Termination

The termination of the vent cap must be in accordance with the local code or the authority having jurisdiction, or in the absence of such, the National Fuel Gas Code, ANSI Z223.1, NFPA 54, Latest Edition.

Do not terminate the vent cap in areas containing acid forming chemicals. Inlet air must not contain any corrosive elements. Any water heater failure due to corrosive elements in the atmosphere is excluded from warranty coverage.

See Figures 3 and 4 for correct Vent Cap Termination Locations.

Figure 3: Alcove Installation Minimums

18” Min.

18” Min.

 

24”

 

Max.

5

Page 5
Image 5
American Water Heater 6510238 installation instructions Vent Cap Termination, Clearances and Accessibility

6510238 specifications

The American Water Heater 6510238 is a noteworthy model in the realm of home water heating solutions. Designed to meet a wide range of domestic hot water demands, this water heater combines efficient performance, advanced technology, and user-centric features.

One of the standout characteristics of the 6510238 is its exceptional energy efficiency. This model is equipped with an advanced insulation system that minimizes heat loss, allowing the unit to maintain optimal water temperatures while using less energy. This not only contributes to reduced utility bills but also aligns with environmentally conscious practices, making it an attractive choice for eco-minded households.

The 6510238 features a high first-hour delivery rating, ensuring that it can meet the hot water needs of busy households without significant wait times. This is largely due to its powerful heating elements, which provide rapid recovery and heating capabilities. Homeowners can enjoy hot showers, clean dishes, and other hot water requirements without the fear of running out.

Another notable aspect of the American Water Heater 6510238 is its durable construction. It is built with a heavy-duty tank that is designed to resist corrosion and extend the lifespan of the unit. Additionally, its glass lining offers extra protection against sediment buildup, further enhancing durability and efficiency.

The unit also incorporates advanced safety features, including a temperature and pressure relief valve, which provides peace of mind to users. This safety mechanism helps prevent the risk of overheating or over-pressurization, ensuring safe operation in various conditions.

Installation and maintenance of the 6510238 have been simplified for user convenience. The water heater is designed with easy-access panels, allowing for straightforward maintenance and service when required. This user-friendly design reduces the time and effort needed for upkeep, making it a preferred option among homeowners.

In summary, the American Water Heater 6510238 stands out with its combination of energy efficiency, high performance, durable construction, and user-friendly features. These characteristics make it a reliable and efficient solution for any household in need of consistent hot water supply. Whether it’s for daily showers, laundry, or cleaning, this water heater is built to deliver optimal performance while ensuring safety and longevity.