Installation
Wiring Guidelines
The maximum wiring distance between the Central Controller and the AV2SM is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts available at the Central Controller’s power supply. The maximum lengths allowable between the AV2SM and the Central Controller are as follows:
Wiring Guidelines
Wiring size Maximum wiring length
181805.7 ft (550.37 m)
201142.4 ft (382.20 m)
22712.2 ft (217.07 m)
24448.9 ft (136.82 m)
Preparing captive wires
1.Strip 0.25 inch of wire insulation off all wires.
2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section.
3.Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively; doing so may strip the threads and damage the connector.
Video output connector
Connect your output display monitor to the VIDEO connector on the front panel using FIG. 4.
Video Cable
AV2SM video output connector (female)
BNC connectors (male)
FIG. 4 VIDEO OUTPUT wiring diagram
Output display monitor connector
(female)
| 4 | AV2SM A/V Switcher |
|
|
|