Programming

 

 

 

Channel Codes (Cont.)

 

 

 

 

 

Operation

Channel #

Description (ON Indicates)

 

 

 

Detection (Cont.)

39

Indicates a momentary loss of loop current (call termination).

 

 

Call Progress Reporting returned to the Axcess AXC-EM when

 

 

call termination is detected.

 

 

Detection of call termination (other end hung up) is usually pro-

 

 

vided by the telephone company and is activated by a momentary

 

 

loss of loop current. However, if this is not available, the DTMF+ is

 

 

triggered by the receiver off-hook tone which occurs approximately

 

 

1 minute after call termination.

 

 

 

 

40

Indicates receiver off-hook tone.

 

 

Call Progress Reporting returned to the Axcess AXC-EM when a

 

 

receiver off-hook is detected.

 

 

 

 

45

Indicates time out while waiting for the dial tone during a wait (W)

 

 

in the Dial Send_Command.

 

 

 

 

47

Indicates dial tone presence.

 

 

 

Distinctive Ring

41-44

The AXB-DTMF+ provides report capability for the type of ring

 

 

received. Distinctive ringing is a service that must be obtained

 

 

from the telephone company. This service allows the same tele-

 

 

phone line to be reached by dialing different telephone numbers.

 

 

The receiving telephone then rings in a distinctive manner accord-

 

 

ing to the number dialed.

 

 

The AXB-DTMF+ provides 4 distinctive ring type patterns.

 

 

These default patterns can be changed and are as follows:

 

 

 

 

41

Default Pattern 1

 

 

The first ring lasts 2 seconds followed by 4 seconds of silence.

 

 

 

 

42

Default Pattern 2

 

 

There are 2 long rings in a 2 second period followed by 4 seconds

 

 

of silence.

 

 

 

 

43

Default Pattern 3

 

 

There are 2 short then 1 long ring in a 2 second period followed by

 

 

4 seconds of silence.

 

 

 

 

44

Default Pattern 4

 

 

There is 1 short, 1 long, and 1 short ring within a 2 second period

 

 

followed by 4 seconds of silence.

 

 

 

AXB-DTMF+ DTMF+ Interface

23

 

 

 

 

Page 27
Image 27
AMX AXB-DTMF+ instruction manual Minute after call termination