AMX AXD-IR+ quick start Overview, Wiring and Installation, Wiring the IR Sensors and Receivers

Models: AXD-IR+

1 2
Download 2 pages 63.61 Kb
Page 1
Image 1
Quick Start Guide

Quick Start Guide

AXD-IR+WallMount Remote IR Receiver

Overview

The AXD-IR+ (FIG. 1) is a remote IR receiver for use with both AMX Axcess/NetLinx Central Controllers and operates via the AXlink bus to remotely control AXlink devices. The AXD-IR+ is in a UniMount wall panel that fits into most US-style single-gang enclosures. The AXD-IR+ works with AMX 38 kHz or 455 kHz IR transmitters.

Note: The AXR-IRSM+ swivel-mount version is also available for wall or ceiling installations:

FIG. 1 AXD-IR+ UniMount IR receiver

AXD-IR+ Specifications

Dimensions (HWD):

4.68" x 2.93" x 1.44" (118.87 mm x 74.42 mm x 36.58 mm)

 

 

Available Colors:

White (FG456-10) and Black (FG456-11)

 

 

Receive Frequencies:

38 / 455 kHz (user-selectable)

 

 

Mounting:

Mounts into most US-style single-gang enclosures.

 

 

Weight:

7.8 oz. (218.4 g)

 

 

Power Consumption:

35 mA

 

 

Wiring and Installation

Set the receive frequency, AXlink device number and IR validation level before installing the AXD-IR+. FIG. 2 illustrates the location of key components on the AXD-IR+ circuit board.

 

 

IR Validation

8-position

 

Jumper Pins

 

 

 

 

 

 

 

 

 

 

AXlink Device

 

 

 

 

AXlink

 

 

 

 

 

DIP Switch

 

 

 

 

Connector

AXD-IR+WallMount Remote IR Receiver Receive Frequency

Jumper Pins

FIG. 2 Location of key components on the AXD-IR+ circuit board

Setting the Receive Frequency

Use the set of jumper pins on the corner of the circuit board to set the receive frequency. FIG. 3 illustrates the configuration of the jumpers..

Note: The unit will not operate with one set of pins configured for 38 kHz and the other set of pins configured for 455 kHz.

To receive 455 kHz (default setting), position both jumpers on pins 1 and 2 (away from the edge of the circuit boards).

To receive 38 kHz, position both jumpers on pins 2 and 3 (near the edge of the circuit boards).

Setting the AXlink Device Number

1.Locate the 8-position Device DIP switch (FIG. 2).

2.Set the DIP switch according to the DIP switch values shown below.

Switch

1

2

3

4

5

6

7

8

Value 1 2 4 8 16 32 64 128

The device number is set by the total value of DIP switch positions that are ON (down). The Axcess software program in your system typically uses device numbers 128 through 255 for the panels.

As an example, the DIP switch in FIG. 4 defines device number 129 (1+128=129).

FIG. 4 Example Device DIP Switch set to 129

Note: If you later change the device number, remove and reconnect the AXlink connector to enter the new device number into memory.

Sensor IR Validation Level

The IR validation level is set on the receiving device (such as an AXC-RCVI).

Setting the IR Validation Level

An IR transmitter must send repetitions of data for the receiver to accept it as valid data. In some installations, a light wall color or other physical condition may interfere with the sensor's or receiver's ability to sense the transmitted signal. The signal may reflect or bounce and become distorted. The receivers can be set to use either two or three repetitions of sequential signals to validate and accept the signal data.

Perform the following steps to set the receiver's IR level.

1.Locate the IR jumper pins (J1) (FIG. 5) on the circuit board (FIG. 2).

 

2

3

 

 

 

 

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting for 2 validations

Setting for 3 validations

FIG. 5 IR validation jumper pin settings

2.Position the IR validation jumper (FIG. 5) to select the number of valid IR data repetitions to be accepted:

Position the jumper at 2 to have the unit validate 2 sequential signals.

Position the jumper at 3 to have the unit validate 3 sequential signals.

Wiring the IR Sensors and Receivers

The AXD-IR+ uses a 4-pin AXlink connector for power and data. If the distance between the receiver and Central Controller exceeds power consumption limits, you can connect a local 12 VDC power supply to the AXlink connector.

IR SNSR 38/455 kHz

IR SNSR 38/455 kHz

Setting for 38 kHz

Setting for 455 kHz

FIG. 3 Receive frequency jumper settings

Page 1
Image 1
AMX quick start Overview, Wiring and Installation, Wiring the IR Sensors and Receivers, AXD-IR+Specifications, Switch