ORDERING INFORMATION FOR ANAHEIM AUTOMATION MICROSTEP DRIVERS AND ACCESSORIES

4 Amp Microstep Driver

MDM40001 (This Manual)

6 Amp Microstep Driver

MDM60001

10 Amp Microstep Driver

MDM10001

40VDC Power Supply

PSA40V4A

65VDC Power Supply

PSA65V5A

80VDC Power Supply

PSA80V4A

Shielded Motor Cable

AA129010S

 

 

MDM40001

This is the model number for a Single Axis, 4 Amp Microstep Driver. The MDM40001 requires a dc power supply (up to 40 volts). The PSA40V4A is the recommended power supply that Anaheim Automation supplies.

MDM60001

This is the model number for a Single Axis, 6 Amp Microstep Driver. MDM60001 requires a 65Vdc power supply (PSA65V5A) that Anaheim Automation provides, purchased separately.

MDM10001

This is the model number for a Single Axis, 10 Amp Microstep Driver. The MDM10001 requires an 80Vdc power supply (PSA80V4A) that Anaheim Automation provides, purchased separately.

PSA40V4A

This is an unregulated 40VDC, 4A power supply.

PSA65V5A

This is an unregulated 65VDC, 5A power supply.

PSA80V4A

This is an unregulated 80VDC, 4A power supply.

PIN DESCRIPTIONS P1

Pin#

Description

 

 

1

Step Clock Input: A positive going edge on this isolated input

 

advances the motor one increment. The size of the increment is

 

dependent on the Microstep Select Inputs of Switch 1.

 

 

2

Direction: This isolated input is used to change the direction of the

 

motor. Physical direction also depends on the connection of the motor

 

windings.

 

 

3

+5 VDC: This input is used to supply current to the Isolated Inputs. A

 

higher voltage may be used, but care should be taken to limit the current

 

through the optocoupler.

 

 

4

ON/OFF: This isolated input is used to enable/disable the output

 

section of the driver. When HIGH (open) the outputs are enabled.

 

However, this input does not inhibit the step clock. Therefore the

 

outputs will be updated by the number of clock pulses (if any) applied to

 

the driver while it had been disabled.

 

 

5

Reset: When LOW, this isolated input will reset the driver (outputs will

 

disable). When released, the driver will be at its initial state (Phase 1&3

 

off, Phase 2&4 full on).

 

 

6

Fault: This OPEN DRAIN output indicates a fault has occurred (ie.

 

short circuit or over temperature). This output is active low.

 

 

7

Fullstep: This OPEN DRAIN output indicates when the driver is

 

positioned at a full step. This output can be used to count the number of

 

full steps the motor has moved, regardless of the number of microsteps

 

in between. This output is active low.

 

 

Table 1 - CONNECTOR P1

#L010068

3

#L010068

4

Page 3
Image 3
Anaheim MDM40001 warranty PSA40V4A, PSA65V5A, PSA80V4A, PIN Descriptions P1, Connector P1