Nordyne SERIES M1B Gas Atmospheric Furnaces, A/C Ready, M1G B, C, D 056, 070 Models, 7101500 8/00

Models: AND M5S SERIES M1B

1 40
Download 40 pages 11.4 Kb
Page 36
Image 36
Gas Atmospheric Furnaces,

36

WIRING DIAGRAM

Gas Atmospheric Furnaces,

A/C Ready, M1G (B, C, D) 056, 070 Models

Figure 42. Gas Atmospheric

 

 

 

 

3 SPEED

 

 

 

NOTES

 

 

 

BLOWER

 

 

 

 

HEATING/

MOTOR

 

 

 

 

1. Incoming power must be polarized. Observe color

 

 

 

 

 

 

COOLING

 

(MED.BLUEHI) (LOW)RED

 

 

 

 

coding. (See furnace data label for electrical

 

 

(HIGH)BLACK

 

WHITE

 

WHITE

information.)

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. If any of the original wires (as supplied with the

 

 

 

 

 

 

G

 

appliance) must be replaced, use 105˚C

 

 

 

 

 

 

 

R

 

Thermoplastic type wire or its equivalent.

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

ON/OFF

CONNECTOR

1

2

3 4

5

6

 

 

HOUSING CAP

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

RED

 

 

 

 

WHITE

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

(SEE NOTE)

 

 

GRAY

RED

 

 

 

TIE WIRE

 

 

 

 

 

 

 

 

 

 

 

AUX. LIMIT

BLUE

BLUE

BLUE

HEATING/COOLING

BLOWER

MOTOR

4 SPEED

(LOW) (HIGH) (MED.HI) (MED. LO)

Furnace, A/C Ready,

BLACK

BLACK

BLUE

GRAY

ORANGE

 

FUSE3A

HI-LIMIT

 

 

 

BLACK

 

 

GRAY

GREEN

 

 

 

TRANSFORMER

 

 

 

 

R

24 V

 

C

 

 

 

FAN

SWITCH

RED BLACK BLUE ORANGE

WHITE

1 2 3 4 5 6

M1GB 056, 070 Models

 

 

 

 

 

SUPPLIED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

115 V

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BY INSTALLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/C

 

 

4

 

6

3

 

 

 

 

 

GREEN

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER

 

 

 

2

 

 

5 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL RESET

 

 

 

 

 

 

GROUND SCREW

 

 

 

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

VENT SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE ELECTRICAL BOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*M1G(C,D) Heating - replace orange wire with red wire (low speed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGENDS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1GB 070 Heating - replace orange wire with blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115V:

 

 

FIELD 115V:

 

 

 

 

 

 

 

 

 

 

 

 

A/C & Heating Speeds: Refer to Table 10, A/C Blower Selection in the manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24V:

 

 

 

 

 

FIELD 24V:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS VALVE

 

 

NOTE: To run at same speed in both heating and cooling mode,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

remove wire from either terminal 4 or 6 on the relay, then attach

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jumper to terminals 4 and 6.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7101500 8/00
(Replaces 7101030)
Page 36
Image 36
Nordyne SERIES M1B Gas Atmospheric Furnaces, A/C Ready, M1G B, C, D 056, 070 Models, Wiring Diagram, M1GB 056, 070 Models