Nordyne AND M5S, SERIES M1B installation instructions Electrical Supply - 120 volts, 60HZ, 1 Ph

Models: AND M5S SERIES M1B

1 40
Download 40 pages 11.4 Kb
Page 31
Image 31
• Electrical Supply - 120 volts, 60HZ, 1 Ph.

Table 10. M1/M5 Furnace Specifications - Factory Settings

31

 

Furnace

Input

Output

Orifice No

E.S.P.

 

Pilot

Ignitor

Comb.

Motor

A/C Ready

 

 

 

Model No

MBtu/h

MBtu/h

Nat.

 

LP

In WC

 

Burner

Direct

Blower

Hp

Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1GB 056

56

45

29

 

45

0.3

 

x

 

 

1/4

3

 

 

 

M1GB 070

70

57

24

 

42

0.3

 

x

 

 

1/4

3

 

 

 

M1GB 077

77

62

21

 

40

0.3

 

x

 

x

1/4

3

 

 

 

M1GB 090

90

72

17

 

36

0.3

 

x

 

x

1/4

3

 

 

 

M1MB 056

56

46

29

 

45

0.3

 

 

x

x

1/4

3

 

 

 

M1MC 056

56

46

29

 

45

0.3

 

 

x

x

1/2

4

 

 

 

M1MB 070

70

57

24

 

42

0.3

 

 

x

x

1/4

3

 

 

 

M1MC 070

70

57

24

 

42

0.3

 

 

x

x

1/2

4

 

 

 

M1MB 077

77

62

21

 

40

0.3

 

 

x

x

1/4

3

 

 

 

M1MC 077

77

62

21

 

40

0.3

 

 

x

x

1/2

4

 

FIGURES

 

M1MB 090

90

72

17

 

36

0.3

 

 

x

x

1/4

3

 

 

 

 

 

 

 

 

M1MC 090

90

72

17

 

36

0.3

 

 

x

x

1/2

4

 

 

 

M1BB 066

66

53

26

 

43

0.3

 

 

x

x

1/4

3

 

&

 

M1BC 066

66

53

26

 

43

0.3

 

 

x

x

1/2

4

 

 

 

 

 

 

TABLES

 

M1BB 086

86

68

18

 

37

0.3

 

 

x

x

1/4

3

 

 

 

 

 

 

 

 

M1BC 086

86

68

18

 

37

0.3

 

 

x

x

1/2

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M5SB 066

66

56

.50 Gph

 

0.3

 

 

x

Burner Model:

1/4

3

 

 

 

M5SC 066

66

56

.50 Gph

 

0.3

 

 

x

AF-10

1/2

4

 

 

 

M5SB 086

86

73

.65 Gph

 

0.3

 

 

x

Spray Angle:

1/4

3

 

 

 

M5SC 086

86

73

.65 Gph

 

0.3

 

 

x

80° A

1/2

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Electrical Supply - 120 volts, 60HZ, 1 Ph.

 

 

 

 

 

 

 

 

 

 

Fuse or Breaker - 15 amps

 

 

 

• Thermostat Circuit - 24 volts, 60HZ, 30 vac

 

 

 

 

• Temperature Rise - 45° F to 75° F

 

 

 

 

 

NOTES:

 

 

• Normal Anticipator Setting - 0.4

 

 

 

 

• High

Altitude

- See

Table 12

(page

32). For

 

 

 

 

• Manifold Pressure - Natural Gas: 3.5” w.c.

 

 

 

 

Canadian Altitudes (2,000’ to 4,500’), reduce the

 

 

 

 

LP Gas: 10” w.c.

 

 

 

 

 

 

gas manifold pressure to 3.0” W.C. for natural gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and to 8” W.C. for LP gas.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 31
Image 31
Nordyne AND M5S, SERIES M1B installation instructions Electrical Supply - 120 volts, 60HZ, 1 Ph