Furance Input

FURNACE

ORIFICE SIZE AND

 

 

 

ALTITUDE - FEET

 

 

 

SEA

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

10,000

MODEL

OUTPUT CAPACITY

LEVEL

M1M/M1G

Orifi ce Size - Nat. Gas

29

29

30

30

30

30

31

31

31

32

Orifi ce Size - LP

45

46

47

47

47

48

48

49

49

50

- 056

 

 

 

 

 

 

 

 

 

 

 

 

 

Output - MBTUH

45.4

41.8

40.1

38.5

37.0

35.5

34.1

32.7

31.4

30.2

 

 

 

M1M/M1G

 

Orifi ce Size - Nat. Gas

24

25

26

27

27

28

28

29

29

30

 

Orifi ce Size - LP

42

42

43

43

43

44

44

45

46

47

- 070

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output - MBTUH

56.7

52.3

50.2

48.2

46.2

44.4

42.6

40.9

39.3

37.7

 

 

 

 

 

 

Orifi ce Size - Nat. Gas

21

23

23

24

25

26

27

28

28

29

M1M - 077

Orifi ce Size - LP

40

41

42

42

42

43

43

44

44

45

 

 

 

Output - MBTUH

61.7

56.9

54.6

52.4

50.3

48.3

46.4

44.5

42.7

41.0

 

 

 

Orifi ce Size - Nat. Gas

21

23

23

24

25

26

27

28

28

29

M1G - 077

Orifi ce Size - LP

40

41

42

42

42

43

43

44

44

45

 

 

 

Output - MBTUH

59.9

55.2

53.0

50.9

48.9

46.9

45.0

43.2

41.5

39.8

 

 

 

Orifi ce Size - Nat. Gas

17

18

19

19

20

21

22

23

24

26

M1M - 090

Orifi ce Size - LP

36

37

38

38

39

40

41

41

42

43

 

 

 

Output - MBTUH

71.7

66.1

63.5

60.9

58.5

56.1

53.9

51.7

49.7

47.7

 

 

 

Orifi ce Size - Nat. Gas

17

18

19

19

20

21

22

23

24

26

M1G - 090

Orifi ce Size - LP

36

37

38

38

39

40

41

41

42

43

 

 

 

Output - MBTUH

69.7

64.2

61.7

59.2

56.8

54.6

52.4

50.3

48.3

46.3

 

 

 

Orifi ce Size - Nat. Gas

26

27

28

28

28

29

29

30

30

30

M1B - 066

Orifi ce Size - LP

43

44

44

44

45

45

46

47

47

48

 

 

 

Output - MBTUH

52.6

48.5

46.6

44.7

42.9

41.2

39.6

38.0

36.5

35.0

 

 

 

Orifi ce Size - Nat. Gas

18

19

19

20

21

22

23

24

26

27

M1B - 086

Orifi ce Size - LP

37

38

39

39

40

41

42

42

43

43

 

 

 

Output - MBTUH

68.2

62.9

60.3

57.9

55.6

53.4

51.2

49.2

47.2

45.3

NOTES: For Canadian high altitude (2,000 - 4,500’), reduce gas manifold pressure to 3.0” W.C. for natural gas and 9” W.C. for LP gas. (Includes 4% Input Reduction for Each 1,000 Feet). These specs do not apply to oil furnace installations. Reference Sources: ANSI Z233.1 & NFPA 54, National Fuel Gas Code.

Table 11. Equivalent Orifice Sizes for High Altitude Installations

M1/M5*B Models and for use with Blower Kit No. 903773 1/4 Hp 3 Speed

Furance Input

Heating Speed

Cooling Speed/ Evap Coil

 

Setting

2 Ton

2-1/2 Ton

 

3 Ton

 

 

086, 090

 

H

L

M

 

H

066, 070, 077

 

M

L

M

 

H

56

 

L

L

M

 

H

M1/M5*C Models and for use with Blower Kit No. 903413 1/2 Hp 4 Speed

 

 

Heating

 

 

Cooling Speed/ Evap Coil

 

 

 

 

 

 

 

 

Furance Input

Speed

 

2 Ton

2-1/2 Ton & 3 Ton

3-1/2 Ton

 

4 Ton

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

077, 086, 090

ML

 

L

ML

MH

 

H

056, 066, 070

L

 

L

ML

MH

 

H

M1/M5*D Models & for use with Blower Kit No. 903890 3/4 Hp 4 Speed

 

 

Heating

 

 

Cooling Speed/ Evap Coil

 

 

 

 

 

 

 

 

Furance Input

Speed

 

2 Ton

2-1/2 Ton & 3 Ton

3-1/2 Ton & 4 Ton

 

5 Ton

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

077, 086, 090

ML

 

L

ML

MH

 

H

056, 066, 070

L

 

L

ML

MH

 

H

Table 12. A/C Blower Speed Selection Chart