Combustion and Ventilation Air

a.) A carbon monoxide (CO) detector and alarm shall be placed on each fl oor level where there are bedrooms. The detector shall comply with NFPA 720 (2005 Edition) and be mounted in the living area outside the bedroom(s).

b.) A (CO) detector shall be located in the room that houses the appliance or equipment and shall:

Be powered by the same electrical circuit as the appliance or equipment. Only one service switch shall power the appliance and the (CO) detector;

Have battery back-up power;

Meet ANSI/UL 2034 Standards and comply with NFPA 720 (2005 Edition); and Approved and listed

 

by a Nationally Recognized Testing

 

Laboratory as recognized under 527

 

CMR.

c.)

A Product-approved vent terminal must

 

be used, and if applicable, a product-

 

approved air intake must be used.

 

Installation shall be in strict compliance

 

with the manufacturer’s instructions. A

 

copy of the installation instructions shall

 

remain with the appliance or equipment

 

at the completion of the installation.

d.)

A metal or plastic identification plate shall

 

be mounted at the exterior of the building,

 

4 feet directly above the location of vent

 

terminal. The plate shall be of suffi cient

 

size, easily read from a distance of eight

 

feet away, and read “Gas Vent Directly

 

Below”.

2.For direct-vent appliances, mechanical vent heating appliances or domestic hot water equipment where the bottom of the

vent terminal and the air intake is installed above four feet above grade the following requirements must be satisfi ed:

a.)

A (CO) detector and alarm shall be

 

placed on each fl oor level where there

 

are bedrooms.The detector shall comply

 

with NFPA 720 (2005 Edition) and be

 

mounted in the living area outside the

 

bedroom(s).

b.)

The (CO) detector shall:

Be located in the room that houses the appliance or equipment;

Be hard-wired, battery powered or both.

Shall comply with NFPA 720 (2005 Edition).

c.) A product-approved vent terminal must be used, and if applicable, a product- approved air intake must be used. Installation shall be in strict compliance with the manufacturer’s instructions. A

copy of the installation instructions shall remain with the appliance or equipment at the completion of the installation.

The information listed below is for reference purposes only and does not necessarily have jurisdiction over local or state codes. Always consult with local authorities before installing any gas appliance.

Combustion and Ventilation Air

US: National Fuel Gas Code (NFGC), Air for Combustion and Ventilation

CANADA: Natural Gas and Propane Instal- lation Codes (NSCNGPIC), Venting Systems and Air Supply for Appliances

Duct Systems

US and CANADA:Air Conditioning Contractors Association (ACCA) Manual D, Sheet Metal and Air Conditioning Contractors National Association (SMACNA), or American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) Fundamentals Hand- book

Electrical Connections

US: National Electrical Code (NEC) ANSI/ NFPA 70

CANADA: Canadian Electrical Code CSA C22.1

Gas Piping and Gas Pipe Pressure Testing

US: NFGC and National Plumbing Codes

CANADA: NSCNGPIC

General Installation

US: Current edition of the NFGC and the NFPA 90B. For copies, contact the National Fire Protection Association Inc., Batterymarch Park, Quincy, MA 02269; or American Gas Association, 400 N.Capitol, N.W.,Washington DC 20001 or www.NFPA.org

CANADA: NSCNGPIC. For a copy, contact Standard Sales, CSA International, 178 Rexdale Boulevard, Etobicoke (Toronto), Ontario, M9W 1R3 Canada

Safety

US:(NFGC) NFPA 54–1999/ANSI Z223.1 and the Installation Standards, Warm Air Heating and Air Conditioning Systems ANSI/NFPA 90B.

Federal Manufactured Home Constructions & Safety Standard (H.U.D. Title 24, Part 3280.707[a][2])

The Standard for Manufactured Home Installations (Manufactured Home Sites, Communities, and Set-Ups) ANSI A225.1 and/ or CAN/CSA-2240 MH Series).

4

Page 4
Image 4
Nordyne SERIES M1B Combustion and Ventilation Air, Duct Systems, Electrical Connections, General Installation, Safety