DVS-36 & DVS-42 INTERMITTENT PILOT OPERATING INSTRUCTIONS
The intermittent pilot (120/24 volt system) is ON when the main burner is ON. When the main burner is OFF the intermittent pilot is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13mm) of the tip of the flame rod.
To adjust:
1.Remove the pilot adjustment cover screw.
2.Turn the inner adjustment screw clockwise to
decrease or counterclockwise to increase pilot flame. Pilot adjustment is shipped at full flow rate. Turn the
inner adjustment screw clockwise if the inlet pres- sure is too high.
3.Replace the cover screw after the adjustment to prevent gas leakage.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Provided on the intermittent pilot wiring harness are two (2) stripped and bare wires that are labeled THERMOSTAT. The wires will be used for attachment of 24 volt thermostat, optional
Installation of Remote Receiver
Place remote receiver on the floor of fireplace behind the louver as far forward as possible.
Attention: The velcro loop and hook are not necessary in this installation but can be used to secure remote receiver.
DVS-36 & DVS-42 INTERMITTENT PILOT WIRING DIAGRAM
Figure 52
ELECTRICAL CONNECTION (Figure 53)
The DVS36/42IP with optional fan requires 120 VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized.
CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI- FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCON- NECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed electrical box is located on the lower right hand side of the fireplace. Wiring must be fed to the electrical box and attached to the receptacle that is provided. Remove the knockout in the installed junction box to accept wiring into the junction box. Install a UL listed cable clamp (not supplied) in the knockout hole. Leave approximately 6" of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite side of receptacle.The ground wire should be attached to the green (neutral) screw.
Install the receptacle into the metal box with. Attach cover plate.
Plug cord set from transformer into receptacle.
JUNCTION BOX |
|
|
|
NEUTRAL |
|
|
|
|
|
|
|
BLACK | WHITE | GROUND | |
|
| ||
|
|
|
Figure 53
Page 31 |