CHART 1 (Figures 20 and 21)

INSTALLATION (continued)

CHART 1 (Figures 20 and 21)

Venting with One (1) 90° Elbow or Two (2) 90° Elbows

Total Vertical

Total Horizontal

(With Fire Box) V

H1 or H1 + H2

4.5' minimum

3' maximum

 

 

4.5' minimum

4' maximum

 

 

5' minimum

8' maximum

 

 

6' minimum

12' maximum

 

 

7' minimum

15' maximum

 

 

8' minimum

20' maximum

 

 

25' maximum vertical

 

20' maximum horizontal run

 

Figure 21 and Chart 1 list examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two (2) 90° elbows as shown in Figure 21 are 20 feet.

Attention: Refer to Figure 10 for additional venting requirements.

10 3/8"

-30

37

5/8"

( 956mm)

 

 

ELBOW

DVS

OF

CENTER

 

OUT

STRAIGHT

 

 

 

Figure 22

12 3/8"

 

36

44

3/4"

114cm

 

118cm

 

 

 

 

-

 

 

 

 

 

DVS

-42

46

3/4"

 

 

 

 

 

ELBOW

DVS

 

OF

CENTER

 

 

 

 

OUT

STRAIGHT

 

 

SEE CHART FOR PERMISSIBLE "H" AND "V" DIMENSIONS

NOTE: H1 AND H2 MUST BE ADDED TOGETHER TO USE CHART

Figure 21

Figure 23

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent termination will be centered (if possible) between two (2) studs. This will avoid any extra framing. All vent kit pipes should be assembled on the unit after the unit is moved into the final position.