Cutting the Hole (Figures 22 and 23)

After the fireplace has been positioned in its permanent location, the hole through the exterior wall of the house can be cut. This hole must be 10" high x 10" wide for DVS-30 or 12 3/8" high x 10 3/8" wide for DVS-36/42 with its center line determined by the

MAX.

3' (914 mm)

amount of vertical arise and horizontal run of the termination. (See Figures 22 and 23) When locating the hole it must be noted that the bottom of the cap must be 12" above the ground level, and top of the cap must be no less than 18" below a combustible projection, and no closer than 9" to any wall running parallel to vent termination. (See Figure 24)

Figure 24

MAXIMUM HORIZONTAL

RUN WITH NO VERTICAL

RISE AND 90° ELBOW

20' (6.1 M)

PIPE STRAPS

MAX.

EVERY 3' (91cm)

 

MAXIMUM HORIZONTAL RUN WITH MINIMUM VERTICAL RISE AND 90° ELBOW

8' (244 cm)

TO BOTTOM

OF UNIT

Figure 25

13369-1-0203

Page 15

Page 15
Image 15
DVS 30-2 installation instructions Max, Cutting the Hole Figures 22