MODEL TH110A-SP-P (120 V)
SUMMARY
uOPTIONS SELECTION
At the back of the thermostat, there are three selection switches to set at your preferences.
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.
uTO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.
uTO RECORD THE (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display.
uTO RECORD THE (ECONOMY) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display .
uTO RECORD THE (VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using the
buttons and press on the and buttons simultaneously until the icon is displayed (app. 3 seconds).
uOPERATING MODES
To select an operating mode, use MODE button.
INSTALLATION
NOTE : The "Problems and Solutions" section at the end of this user's guide will help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation which has a RESISTIVE load not exceeding 2400 W (20 A) @ 120 VAC such as electric baseboards, radiant ceilings and floors, electric con- vectors, etc. It is not compatible with a low voltage controller used by a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a
PARTS INCLUDED
-One (1)
-Two (2)
-Four (4) solderless connectors (for copper wire)
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean and free from obstructions.
1) Connecting wires and mounting thermostat
Connect the rear thermostat wires to the 120 V LINE and to the load using solderless connectors for copper wires. See schematic diagram.
Push the excess wire back into the electrical box to prevent interference with the thermostat. Secure the thermostat using two (2)
AUTO: | Runs the program. | or | shows temperature setting | ||
| and can override temporarily your programming up to the | ||||
| next program. |
|
|
|
|
MAN: | Maintains the selected temperature. | or | changes | ||
| the temperature setting. |
|
|
|
BEFORE
OLD
THERMOSTAT
SUPPLY
AFTER
120 V LINE
BLACK
BLACK
BLACK |
WHITE |
BLACK |
120 VAC B
B
W
60 HZ W
B | W |
| |
B | W |
|
LOAD
LOAD
NOTE : All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when connecting with aluminum conductors.
Power-up
2400 W (NI) @ 120 Vca |
Set the On/Stand by switch to On.
When power is applied for the first time, the display must show the time 00:00, the room
temperature and the Manual mode icon ( ). Other information might show up on the display if installation is defective or does not comply with the instructions.
NOTE : The On/Stand by switch set to Stand by will place the thermostat in sleep mode. Ideal for summertime.