Anetsberger Brothers CF14 warranty FRYER TROUBLESHOOTING GUIDE Continued, Problem, Cause, Remedy

Models: CF14

1 16
Download 16 pages 37.34 Kb
Page 14
Image 14
recalibrated.

FRYER TROUBLESHOOTING GUIDE (Continued)

PROBLEM

CAUSE

REMEDY

 

 

 

Liquid shortening does

1. Low gas supply pressure [less than 6

1. Measure the gas supply pres-

not reach the desired

W.C. for natural gas; (11W.C. for pro-

sure.

temperature for frying.

pane) when all other gas-powered equip-

Contact your local gas supplier

 

ment is operating], causing reduced heat

to obtain adequate gas supply

 

from main burners.

pressure.

 

2. Low gas manifold pressure [less than 3½

2. Measure the gas pressure at

 

W.C. for natural gas; (10W.C. for pro-

the fryer’s manifold pressure

 

pane).

tap. Adjust the manifold pres-

 

 

sure (see Figure 6), as neces-

 

 

sary: [a] Unscrew (and re-

 

 

tain) the threaded Main Burner

 

 

Regulator Adjustment Cover. [b]

 

 

Use a flat-blade screwdriver to

 

 

turn the regulator adjustment

 

 

screw (clockwise to increase;

 

 

counterclockwise to decrease)

 

 

to reset the pressure adjust-

 

 

ment. [c] Reinstall, and tighten,

 

 

the Regulator Adjustment

 

 

Cover, when finished.

 

3. Loosen knob on thermostat; or thermostat

3. Stir the shortening to mix the

 

requires calibration (temperature setting

hot shortening with some from

 

differs by about 10°F from measured

the lower ‘cool zone’ and allow

 

shortening temperature).

it to sit for 5 minutes. Turn the

 

 

thermostat knob until it ‘clicks’

 

 

on (causing the main burners to

 

 

flame); note the setting where

 

 

this occurs. Turn the thermo-

 

 

stat knob until it ‘clicks’ off

 

 

(causing the main burners to go

 

 

out); note the setting where this

 

 

occurs. Repeat this tempera-

 

 

ture ‘click points’ step at least

 

 

three times to ensure that

 

 

the shortening temperature has

 

 

stabilized.

 

 

Measure the temperature of

 

 

the shortening by inserting an

 

 

accurate thermometer about

 

 

4 inches into the shortening to

 

 

measure its temperature. If the

 

 

temperature difference between

 

 

the measured temperature and

 

 

the thermostat setting is 10°F

 

 

or less, the thermostat can be

 

 

recalibrated.

 

 

 

14

Page 14
Image 14
Anetsberger Brothers CF14 warranty FRYER TROUBLESHOOTING GUIDE Continued, Problem, Cause, Remedy, recalibrated