Anetsberger Brothers CF14 warranty Brated

Models: CF14

1 16
Download 16 pages 37.34 Kb
Page 15
Image 15

FRYER TROUBLESHOOTING GUIDE (Continued)

PROBLEM

CAUSE

REMEDY

 

 

 

Liquid shortening does

 

Recalibrate the thermostat by:

not reach the desired

 

(a) removing the cap on the

temperature for frying.

 

thermostat control knob; (b)

(Continued)

 

loosening the center brass hex

 

 

nut portion of the knob; (c) turn

 

 

the pointer portion of the knob to

 

 

the measured temperature value

 

 

of the thermostat setting.

 

 

Tighten the brass hex nut to lock

 

 

the adjustment. Replace the

 

 

cap on the knob.

 

4. Thermostat setting is more than 20°F dif-

4. Check the thermostat setting

 

ferent than measured shortening tempera-

against an accurate measure of

 

ture.

the shortening temperature. If

 

 

the temperature difference is

 

 

greater than 20°F, the thermo-

 

 

stat can possibly be recali-

 

 

brated.

 

 

Recalibrate the thermostat by:

 

 

(a) removing the cap on the

 

 

thermostat control knob; (b)

 

 

loosening the center brass hex

 

 

nut portion of the knob; (c) turn

 

 

the pointer portion of the knob

 

 

to the measured temperature.

 

 

Tighten the brass hex nut to lock

 

 

the adjustment. Replace the

 

 

cap on the knob.

 

 

If this calibration is unsuccess-

 

 

ful, the thermostat has failed and

 

 

must be replaced.

 

 

 

15

Page 15
Image 15
Anetsberger Brothers CF14 warranty Brated