Chapter 7 Menu description tables

7-5-6 WHITE BALANCE MODE

Item/

 

 

Variable

Remarks

Data storage

range

 

 

 

 

 

 

FILTER INH

 

 

ON

For selecting whether or not to keep the AWB

 

 

 

OFF

memory (Ach, Bch) data for each filter.

 

 

 

 

ON: The data is kept in the two Ach and Bch

 

 

 

 

memories for each filter used.

C U

F

E

 

OFF: The data is kept for each filter.

 

 

 

SHOCKLESS AWB

OFF

For selecting whether to set SHOCKLESS

 

 

 

FAST

AWB to ON (FAST/NORMAL/SLOW1-3) or

 

 

 

NORMAL

OFF.

 

 

 

SLOW1

The SHOCKLESS AWB function will work

 

 

 

SLOW2

only when MEM has been selected at the

 

 

 

SLOW3

AWB A item and AWB B item settings for the

 

 

 

 

A and B positions of the WHITE BAL switch,

 

 

 

 

and it ensures that no shocks will result when

 

 

 

 

the WHITE BAL switch is switched between

 

 

 

 

the PRST, A and B settings.

 

 

 

 

In addition, the switching time can be

C U

F

E

 

selected.

 

 

 

 

 

AWB AREA

 

 

25%

For selecting the AWB detection area.

 

 

 

50%

25%: An area near the screen center

 

 

 

90%

equivalent to 25% of the screen is

 

 

 

 

detected.

 

 

 

 

50%: An area near the screen center

 

 

 

 

equivalent to 50% of the screen is

 

 

 

 

detected.

 

 

 

 

90%: An area equivalent to 90% of the

C U

F

E

 

screen is detected.

 

 

 

 

 

AWB & ABB

 

 

ON

For selecting whether or not to reset the GAIN

OFFSET

 

 

OFF

and PED values on the ROP menu when

 

 

 

 

AWB or ABB is executed. When set to OFF,

 

 

 

 

GAIN will be reset when AWB is executed

 

 

 

 

and PEDESTAL will be reset when ABB is

 

 

 

 

executed.

 

 

 

 

ON: The values are not reset.

C U

F

E

 

OFF: The values are reset.

 

 

 

COLOR TEMP PRE

3200K

For selecting the AWB PRE color

 

 

 

:

temperature.

C U

F

E

5600K

 

 

 

 

 

 

AWB A

 

 

MEM

For selecting the allocation of the WHITE BAL

 

 

 

VAR

switch position and Ach.

 

 

 

 

MEM: The switch position and Ach are

 

 

 

 

allocated as memory values when

 

 

 

 

AWB is executed.

 

 

 

 

VAR: The color temperature of A can be set

 

 

 

 

to vary using the COLOR TEMP A

C U

F

E

 

menu item.

 

 

 

 

COLOR TEMP A

 

3200K

For setting the color temperature when AWB

 

 

 

:

A has been set to VAR.

C U

F

E

5600K

 

AWB B

 

 

MEM

For selecting the allocation of the WHITE BAL

 

 

 

VAR

switch position and Bch.

 

 

 

 

MEM: The switch position and Bch are

 

 

 

 

allocated as memory values when

 

 

 

 

AWB is executed.

 

 

 

 

VAR: The color temperature of B can be set

 

 

 

 

to vary using the COLOR TEMP B

C U

F

E

 

menu item.

 

 

 

 

COLOR TEMP B

 

3200K

For setting the color temperature when AWB

 

 

 

:

B has been set to VAR.

C U

F

E

5600K

 

7-5-7 USER SW GAIN

Item/

 

 

 

 

Variable

 

Remarks

Data storage

 

 

 

range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.GAIN

 

 

2

 

 

For selecting whether or not to enable a

30 dB

 

 

 

O

 

 

setting of 30 dB for SUPER GAIN.

 

 

 

 

 

 

 

2

: The 30 dB setting is enabled.

C U

F

E

 

 

 

 

O : The 30 dB setting is disabled.

 

 

 

 

 

 

 

36 dB

 

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting of 36 dB for SUPER GAIN.

 

 

 

 

 

 

 

2

: The 36 dB setting is enabled.

C U

F

E

 

 

 

 

O : The 36 dB setting is disabled.

 

 

 

 

 

 

 

42 dB

 

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting of 42 dB for SUPER GAIN.

 

 

 

 

 

 

 

2

: The 42 dB setting is enabled.

C U

F

E

 

 

 

 

O : The 42 dB setting is disabled.

 

 

 

 

 

 

 

48 dB

 

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting of 48 dB for SUPER GAIN.

 

 

 

 

 

 

 

2

: The 48 dB setting is enabled.

C U

F

E

 

 

 

 

O : The 48 dB setting is disabled.

 

 

 

 

 

 

 

DS.GAIN

 

 

2

 

 

For selecting whether or not to enable a

6 dB: (25P)

 

 

O

 

 

setting increase of 6 dB (25P) for DS.GAIN.

 

 

 

 

 

 

 

2

: The 6 dB setting increase is enabled.

C U

F

E

 

 

 

 

O : The 6 dB setting increase is disabled.

 

 

 

 

 

 

 

DS.GAIN

 

 

2

 

 

For selecting whether or not to enable a

10 dB: (16P)

 

 

O

 

 

setting increase of 10 dB (16P) for DS.GAIN.

 

 

 

 

 

 

 

2

: The 10 dB setting increase is enabled.

C U

F

E

 

 

 

 

O : The 10 dB setting increase is disabled.

 

 

 

 

 

 

12 dB: (12P)

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting increase of 12 dB (12P) for DS.GAIN.

 

 

 

 

 

 

 

2

: The 12 dB setting increase is enabled.

C U

F

E

 

 

 

 

O : The 12 dB setting increase is disabled.

 

 

 

 

 

 

15 dB: (8P)

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting increase of 15 dB (8P) for DS.GAIN.

 

 

 

 

 

 

 

2

: The 15 dB setting increase is enabled.

C U

F

E

 

 

 

 

O : The 15 dB setting increase is disabled.

 

 

 

 

 

 

20 dB: (5P)

 

2

 

 

For selecting whether or not to enable a

 

 

 

 

O

 

 

setting increase of 20 dB (5P) for DS.GAIN.

 

 

 

 

 

 

 

2

: The 20 dB setting increase is enabled.

C U

F

E

 

 

 

 

O : The 20 dB setting increase is disabled.

 

 

 

 

 

 

 

 

 

The underlining in the variable range column indicates the setting in the preset mode.