The battery should remain on the charger until just prior to being used. The patented Lifesaver maintenance routine keeps the battery 100% charged and balanced by eliminating the typical self-discharge that can cripple a battery that is stored for any length of time on the shelf. Do not remove the Logic Series batteries from the charger more than 8 hours prior to actual use. For best results, this battery should be returned to the Logic Series charger within 48 hours of being used. Please read the individual charger Owner’s Manual to become acquainted with the many unique features of the Logic Series chargers.

“OVER-DISCHARGED” BATTERIES

An “over-discharged” voltage state is caused by leaving a battery operated device unattended and allowing the battery to drain beyond the low voltage warning point of the equipment.

Low voltage “over-discharged” batteries can also be caused by allowing batteries to remain off the charger for extended periods. Returning batteries to the Logic Series LifesaverCharger as soon as possible after use, and leaving batteries in the Lifesaver mode until just prior to using will avoid this type of “over-discharge” condition.

A battery that has been inadvertently allowed to become “over-discharged” will automatically trigger a special rejuvenation routine contained in all Anton/Bauer Logic Series Chargers. In such cases the red/green alternating LED’s, on the charger, indicate that the automatic rejuvenation cycle is bringing the battery back up to a safe charging voltage. When the Logic Series Charger verifies there are no thermal violations, it will begin a complete charge cycle (Red flashing LED).

In the extreme case that a battery is over-discharged, the rejuvenation charge routine will not be initiated by the charger until all other batteries have completed their fast charge routines. Therefore, an extremely over-discharged battery can be installed on a Logic Series Charger without the charger indicating recognition.

- 4 -

Page 6
Image 6
Anton/Bauer Trimpac 13/14, ProPac 13/14 owner manual OVER-DISCHARGED Batteries