MIRACLE STEAMER

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.

Problem

Possible Cause

Corrective Action

Control Display is Blank (power On/

The power cord is not correctly

Plug the power cord into the appro-

Off switch is On but indicator light is

plugged in.

priate outlet.

off).

The power cord and/or electrical

Inspect electrical wire, plug, and

 

plug is damaged.

receptacle.

 

The main electrical panel circuit

Reset circuit breaker. Contact your

 

breaker is off or has been tripped.

maintenance person or Authorized

 

 

Service Agency if it trips again.

 

Switch is inoperable.

Contact your maintenance person or

 

 

Authorized Service Agency for ser-

 

 

vice.

Control Display is blank (power On/

Control Board is inoperable

Contact your maintenance person or

Off switch is on and indicator light is

Transformer is inoperable.

Authorized Service Agency for ser-

on).

 

vice.

Loose, burnt, or broken wires in cir-

 

 

 

cuit.

 

Unit does not heat up (Control

Hi-Limit Thermostat is tripped or

Reset the Hi-Limit Thermostat

Display is on)

inoperable.

according to the Operations sec-

 

Solid State Relay is inoperable.

tion of this manual. If the Hi-Limit

 

 

Thermostat requires continuous

 

Thermocouple is inoperable.

 

resetting, contact your Authorized

 

Control Board is inoperable.

 

Service Agency for service.

 

Steam Generator is inoperable.

 

 

Loose, burnt, or broken wires in cir-

 

 

cuit.

 

The unit’s main electrical panel cir-

Damaged receptacle, plug, or cord;

Turn the unit off, allow it to cool to

cuit breaker trips.

a loose connection or an internal

room temperature, and then restart

 

component failure.

the unit. Contact your maintenance

 

 

person or Authorized Service Agency

 

 

if the condition repeats.

Water leaking inside electrical hous-

Pinhole leak in rubber hoses (MS-

Replace hoses.

ing.

150/155/355).

 

 

Loose or damaged water line tubes

Tighten or replace tubes and/or fit-

 

and/or fittings inside electrical hous-

tings.

 

ing.

 

ERR” appears in the Control

Programming and/or SHO and

Reset the Control Board as

Display.

H2O values were adjusted/changed

described in the Programing section

 

improperly.

of this manual. See Fault Codes.

P/N 1010699 Rev. M 12/06

19

Page 19
Image 19
Antunes, AJ MS-150/155 owner manual Troubleshooting, Problem Possible Cause Corrective Action

MS-150/155 specifications

The Antunes AJ MS-150/155 series is a premium line of commercial food service equipment designed to meet the evolving needs of the fast-paced food industry. Known for its reliability and efficiency, this series includes innovative features that cater to both high-volume and diverse menu offerings.

One of the standout attributes of the Antunes AJ MS-150/155 is its advanced cooking technology. Equipped with a precise digital control system, it allows for accurate temperature settings and time management, ensuring consistent cooking results with every use. This precision is crucial for maintaining food quality and meeting safety standards, particularly in busy kitchen environments.

The AJ MS-150/155 series incorporates a user-friendly interface with intuitive controls, making it easy for staff to operate even during rush hours. The digital display provides real-time monitoring of cooking processes, reducing the risk of errors and enhancing operational efficiency. Moreover, the units feature programmable cooking cycles, allowing operators to save specific settings for different menu items, thereby streamlining the food preparation process.

Durability is a hallmark of the Antunes brand, and the AJ MS-150/155 does not disappoint. Constructed with high-grade stainless steel, these units are built to withstand the rigors of a commercial kitchen. The materials used not only contribute to the longevity of the equipment but also make cleaning and maintenance straightforward, ensuring that hygiene standards are upheld.

In terms of versatility, the AJ MS-150/155 is suitable for various cooking applications, including toasting, baking, and even grilling. This multifunctionality provides food service operators with the flexibility they need to cater to a broad range of menu options, from sandwiches and wraps to baked goods and snacks.

Energy efficiency is another notable feature of the AJ MS-150/155 series. Designed to minimize energy consumption without compromising performance, the equipment can help businesses reduce their energy costs and environmental impact.

In summary, the Antunes AJ MS-150/155 series stands out as a reliable solution for commercial kitchens seeking efficiency, durability, and versatility. With its advanced technology and user-friendly features, this equipment is poised to enhance food preparation processes and support culinary creativity, making it an invaluable asset for any food service operation.