APC BR700G, RS 700 manual Troubleshooting, Problem, Possible Cause, Corrective Action

Models: BR700G

1 8
Download 8 pages 6.35 Kb
Page 6
Image 6
Troubleshooting

Troubleshooting

Problem

Possible Cause

Corrective Action

 

 

Back-UPS will not switch on. The unit is not connected to utility power.

Ensure that the unit is securely connected to an

 

 

AC outlet.

The circuit breaker has been tripped.

Disconnect non-essential equipment from the unit. Reset the circuit breaker. Re-connect equipment one item at a time. If the circuit breaker is tripped again, disconnect the device that caused the trip.

 

The internal battery is not connected.

Connect the battery.

 

 

The utility input voltage is out of range.

Adjust the transfer voltage and sensitivity range.

 

The unit does not provide

Ensure that essential equipment is not

Disconnect equipment from the SURGE ONLY

 

power during a utility power

plugged into a SURGE ONLY outlet.

outlet and re-connect to a BATTERY BACKUP

outage.

 

outlet.

 

 

 

 

The unit is operating on

The plug has partially pulled out of the wall

Ensure that the plug is fully inserted into the

battery power, while connected

outlet, the wall outlet is no longer receiving

wall outlet. Ensure that the wall outlet is

to utility power.

utility power, or the circuit breaker has been

receiving utility power by checking it with

 

tripped.

another device.

 

 

 

 

 

The unit is performing an automatic self

No action is necessary.

 

test.

 

 

 

 

 

 

 

The utility input voltage is out of range, the

Adjust the transfer voltage and sensitivity range.

 

frequency is out of range, or the waveform

 

 

 

is distorted.

 

 

The unit does not provide the expected amount of backup time.

Battery Backup outlets may be fully or

Disconnect non-essential equipment from the

improperly loaded.

BATTERY BACKUP outlets and connect the

 

equipment to SURGE ONLY outlets.

 

 

The battery was recently discharged due to a

Charge the battery cartridge for 16 hours.

power outage and has not fully recharged.

 

 

 

The battery has reached the end of its useful

Replace the battery.

life.

 

The REPLACE BATTERY

The battery has reached the end of its useful

Replace the battery.

indicator is illuminated.

life.

 

 

 

The OVERLOAD indicator is The equipment connected to the unit is

Disconnect non-essential equipment from the

illuminated.

drawing more power than the unit can

BATTERY BACKUP outlets and connect the

 

provide.

equipment to SURGE ONLY outlets.

 

 

The SYSTEM FAULT indicator is There is an internal fault.

Determine which internal fault message is

illuminated, all the front panel

 

displayed by matching the number displayed on

indicators are flashing.

 

the LCD with the corresponding Fault Message

 

 

(see System Faults) and contact APC Technical

 

 

Support.

Power is not supplied to some outlets.

Power to the Controlled Outlets has intentionally been turned off.

Confirm that the correct peripherals are connected to Controlled Outlets. If this feature is not desired, disable the Power-Saving Master and Controlled Outlets.

The Controlled Outlets are not supplying power, even though the Master device is not in sleep mode.

The Master Outlet threshold may be incorrectly set.

Adjust the threshold when the Master outlet signals the Controlled Outlets to shut down.

6

Back-UPS® RS Installation and Operation

Page 6
Image 6
APC BR700G, RS 700 manual Troubleshooting, Problem, Possible Cause, Corrective Action