These outlets are powered whenever the Back-UPS RS is switched ON. During a power outage or other utility problems (brownouts,
over-voltages), these outlets will be powered for a limited time by the Back-UPS RS. Plug your computer, monitor, and one other data-sensitive device (external disk or tape drive) into these outlets.
Data Port
Battery Back-up plus
Surge Protection
Connect the Equipment
2Place the Back-UPS to avoid: - Direct sunlight;
- Excessive heat;
- Excessive humidity or contact with fluids.
If you want to use the management function of your Back-UPS, you shall acquire the communication kit (part number AP9937).
The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.
If you have the communication kit, connect the interface cable to the data port at the Back-UPS rear and the other end of the cable to the USB port of your computer.
Connect Fax / modem (ADSL) / phone
Back-UPS RS protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back-UPS RS as shown.
Modem Phone / FAX
Computer USB port
Modem/Phone/Fax
Wall Outlet
Wall Outlet
Before connecting the battery, unplug the Back-UPS from wall outlet and also all equipement connected to the UPS. This is not a hot swap unit.
NOTE: Small sparks may occur during battery connection.

User manual

Back-UPS®RS BR1200 BI-BR

w w w . a p c . c o m

Connect Battery

1For your security, Back-UPS RS is provided with the battery cable disconnected. The UPS only will work after the cable is connected to the battery terminal.

1

Press the lock that is under the UPS

2

Connect the battery cable to its terminal

and pull the bezel at the bottom.

(positive pole)

 

 

2)Press the top of the plastic panel and twist the bottom part as shown in the picture.

3

Engage the superior part of the panel in the

holes and gently push it till it locks.

 

1)Press the lock that is under the product.

Some resistance to dismount the plastic panel will be noticed.

This is normal.

Switch on your Back-UPS RS

3Press the ON/OFF switch to power the unit. This will initiate an automatic test.

A single short beep and the green On-Line indicator confirms that Back-UPS is on and ready to protect your equipments. The Back-UPS RS is on and ready to provide protection.

The Back-UPS RS should charge for at least 12 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF.

In case you have the AP9937 Communication Kit, install PowerChute Personal

Edition® software

To install the software, insert the CD-ROM into the drive and follow the on-screen instructions. Refer to the software documentation to get further using instructions and functionality.

Status

Indicación

Definición

 

Visual / Audible

 

 

 

 

Online – Operation is normal

Led on.

The utility power is on security levels.

(Green indicator).

Beeping 4 times every

UPS is running on battery mode and utility

 

 

30 seconds.

power is not available at the power outlet.

 

Beeping once every second.

UPS will shutdown in one minute.

 

 

 

Voltage Regulation –

Led on.

The power from the utility power is above or

(Yellow indicator).

 

under the range specified for product.

 

 

UPS is automatically regulating voltage

 

 

for security levels.

Overload –

ELed on, constant tone

UPS is overloaded: disconnect part

(Red indicator)

 

of the load connected.

 

 

 

Check battery

Flashing once every

The battery automatic test was not successfully

 

second.

completed or battery is disconnected.

 

 

Consult “troubleshooting” section.

 

 

 

Operation indication

The Back-UPS RS indicates operating status using a combination of audible and visual indicators (leds). Refer to the “Troubleshooting”

section to get further information.

FrontalRear

Legend:

1

– Power LED

6

– 110V Circuit breaker

2

– Tension adjustment LED

7

– Power cable

3

– Overloaded/verify LED

8

- Data Port

4

– Power switch

9

- Modem / Phone / Fax Port

5

– 220V Circuit breaker

10 -Wall Outlet

Replacing the battery

When Back-UPS indicates the need of replacing battery, you should order an APC certified battery pack and proceed as following described:

NOTE: Small sparks may occur during battery connection.

Before connecting the battery, unplug the Back-UPS from wall outlet and also all equipement connected to the UPS. This is not a hot swap unit.

1

1 Press the lock that is under the UPS

and pull the bezel by the bottom.

 

2)Press the top of the plastic panel and twist the bottom part as shown in the picture.

1) Press the lock that is

Some resistance to

dismount the plastic

under the product.

panel will be noticed.

 

This is normal.

4 Turn the cap down and remove it.

2

Disconnect the central wires and the protection

fuses from battery terminals.

 

5

Remove battery package from the product and

replace it. UPS is supplying battery power to

the load connected to the Battery outlets.

3

Disconnect the battery and, then, unscrew

the frontal metallic panel

 

6

Reconnect all cables in the inverse order of

disassembling. Engage the metal cap and

screw it again. Engage the plastic panel superior part and press it softly on rear until it locks.

Page 1
Image 1
APC RS BR1200 BI-BR user manual Replacing the battery, Connect Battery, Switch on your Back-UPS RS, Operation indication

RS BR1200 BI-BR specifications

The APC RS BR1200 BI-BR is an innovative and reliable uninterruptible power supply (UPS) that is designed to provide exceptional backup power for critical electronic devices in various environments. This UPS is particularly favored in small to medium-sized businesses, as well as for home office setups, due to its combination of efficiency, affordability, and essential features.

One of the main features of the APC RS BR1200 is its robust power capacity. With a 1200 VA power rating, this UPS can handle a wide range of devices, including computers, network equipment, and peripheral devices. This capability ensures that users can maintain productivity and prevent data loss during unexpected power outages or fluctuations.

The UPS is equipped with advanced battery technology, ensuring reliable performance and extended runtime. The inclusion of a sealed lead-acid battery guarantees durability and requires minimal maintenance over time. Additionally, the RS BR1200 features a battery replacement indicator that alerts users when it's time to replace the batteries, ensuring optimal functionality.

Another key technology found in the APC RS BR1200 is its Automatic Voltage Regulation (AVR) system. This feature stabilizes the output voltage, providing consistent power to connected devices even during voltage sags or spikes. AVR technology helps to prolong the life of connected equipment, reducing the risk of damage caused by electrical issues.

The RS BR1200 also includes multiple output sockets, allowing users to connect several devices simultaneously. This convenience makes it an ideal choice for home offices or small server rooms where multiple devices require backup protection. The UPS also features USB connectivity, enabling users to monitor the system status and receive notifications through their computers.

Additionally, the APC RS BR1200 is designed with user-friendly characteristics, such as a clear LED display. This display provides real-time information on battery status, load levels, and any alerts, making it easier for users to manage their power needs. The compact and sleek design of the UPS allows it to fit seamlessly into any workspace without occupying excessive space.

In summary, the APC RS BR1200 BI-BR is a highly efficient and versatile UPS that combines essential features, advanced technologies, and user-friendly characteristics. Its power capacity, battery technology, AVR system, and multiple connectivity options make it an excellent choice for protecting critical electronic devices against power interruptions. By investing in the APC RS BR1200, users can ensure uninterrupted performance and safeguard their valuable data and equipment.