LOCATION CONSIDERATIONS

LOCATION CONSIDERATIONS

1.Install Unit Indoors: It is recommended that the Model 8100 ERV be mounted in a conditioned space.. If the unit is mounted in an area where the temperature may drop below 32°F or exceed 100°F, all duct work in the unconditioned space must be insulated..

2.Mounting: The recommended mounting location is on the basement foundation wall, or a stud wall with easy access to the HVAC system.. The unit may also be mounted to basement ceiling joists..

3.Mounting Kit: The unit must be mounted with the mounting kit provided..

4.Power: Outlet within 30” of unit..

5.Service Clearances: Allow a minimum of 36” clearance around the access door.. Allow for 12” of clearance to access duct connections, on/ off switch and wiring connections.. (See Figure 3..)

Figure 3 – Dimensions and Location Considerations

 

 

 

 

 

CEILING MOUNTING HOLES

EXTERNAL CONTROL WIRING ACCESS

CEILING MOUNTING HOLES

 

 

 

 

 

ON / OFF

 

 

 

 

 

SWITCH

 

 

 

RETURN

 

 

WALL

 

 

STALE AIR

 

 

 

 

 

 

WALL

MOUNTING

 

20-9/16"

 

 

MOUNTING

HOLES

 

 

 

HOLES

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

FRESH AIR

 

 

6" ROUND

12-3/4"

2"

 

2"

 

COLLARS

 

 

37-7/16"

 

 

6" ROUND COLLARS

 

 

 

 

 

 

12"

 

12"

 

 

 

SERVICE

36"

 

 

 

CLEARANCE

 

 

 

 

 

 

 

 

 

 

90-1743

 

 

 

 

 

3

Page 3