APW EZFILL HOT FOOD WELLS
PART NO'S BEGINNING WITH WHFW
|
|
|
|
|
|
|
|
| INSTALLATION | ||
|
|
|
|
|
| 1. | Follow general installation instructions on | ||||
|
|
|
|
|
| page 3. |
|
|
| ||
|
|
|
|
|
| 2. | Make applicable | ||||
|
|
|
|
|
| Note: Unit is designed for installation in | |||||
|
|
|
|
|
| stainless steel tops. Optional wood mounting | |||||
|
|
|
|
|
| kit available. |
|
|
| ||
|
|
|
|
|
| 3. | Apply putty tape to the underside perimeter | ||||
|
|
|
|
|
| of the well rim outer edge. |
| ||||
|
|
|
|
|
| 4. | Apply a 1/4" (.6) bead of silicone sealant | ||||
|
|
|
|
|
| adjacent to the putty tape on the well flange. | |||||
|
|
|
|
|
| 5. | Drop well into opening from the top and | ||||
|
|
|
|
|
| push down until entire parameter of rim is flush | |||||
|
|
|
|
|
| with the counter surface. |
| ||||
|
|
|
|
|
| 6. | From below the counter surface insert an 8" | ||||
|
|
|
|
|
| to 10" (20 to 25 cm) flat tip screwdriver into the | |||||
|
|
|
|
|
| locking ring tab slots and twist in a clockwise | |||||
|
|
|
|
|
| motion to lock well in place. |
| ||||
|
|
|
|
|
| 7. | Trim excess putty and sealant from around | ||||
|
|
|
|
|
| well rim. |
|
|
| ||
|
|
|
|
|
| 8. | Mount control to front panel using hardware. | ||||
|
|
|
|
|
| Maintain 4" (10.2) clearance between well and | |||||
|
|
|
|
|
| front panel. |
|
|
| ||
|
|
|
|
|
| 9. | Check nameplate for proper voltage. | ||||
|
|
|
|
|
| Connect power. |
| ||||
|
|
|
|
|
| 10. Connect overflow tube onhot food well to | |||||
|
|
|
|
|
| suitable tubing to handle 212 F water. Run to | |||||
| 1. Water fill is 3/8 (1.0) tubing connection on left | open drain. |
|
|
| ||||||
| back of left controls |
|
|
| Note: Electrically connect units to comply | ||||||
| 2. Main drain is 3/4 female NPT. |
|
| with local and NEC codes. |
| ||||||
|
|
|
|
|
|
|
|
| |||
| GENERAL SPECIFICATIONS (APW EZFILL HOT | FOOD WELLS) |
| ||||||||
|
|
|
|
|
|
|
|
|
| ||
MODEL | OUTSIDE DIMENSIONS |
| CUT OUT |
| CONTROL CUT OUT |
| SHIP WT. | ||||
|
|
|
|
|
|
|
|
|
|
| |
| A | B | C | D | E |
| F |
| G |
|
|
15.21" | 12.71" | 13.49" | 13.75" | 11.50" |
| 5.0" |
| 12.5" |
| 22 Lbs. (10.6 Kg) | |
(38.6) | (32.3) | (34.3) | (34.9) | (29.2) |
| (12.7) |
| (31.8) |
| ||
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OPTIONS | |||||
Description: Lever Operated Drain Valve | Stock No.: 56360 |
|
|
| Drain Manifold: Fabricated to Unit, Required | |||||
|
|
| ELECTRICAL SPECIFICATIONS | |||||||
|
|
|
|
|
|
|
| |||
MODEL | Electrical Ratings 500 EA. @ 208V / 660 EA. @ 240V |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
| Volts | Watts | Amps |
| Max Amps |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
208/240 | 500/660 | 2.4/2.75 |
| n/a |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| NOTE: | ||||||||
|
|
|
|
|
|
|
|
|
|
|
| OPERATION |
|
|
|
|
| CLEANING | |||
|
|
| ||||||||
1. Follow General Operating Instructions on page 3. |
| 1. Follow General Cleaning Instructions on page 3. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
5