Page 4 of 5
GETTING YOUR HEAT PUMP STARTED & STOPPED
ATTENTION:
THIS IS A
INITIAL START UP
1. Start the water circulator pump.
NOTE: THE POOL FILTER PUMP MUST BE OPERATING FOR THE HEAT PUMP TO BEGIN HEATING. ANYTIME THE POOL FILTER PUMP IS TURNED OFF, THE HEAT PUMP WILL ALSO BE OFF.
2.Ensure that the unit has power connected; display should be illuminated.
3.If the display is blank, be certain the breaker and heater disconnect are switched to “ON”.
HOW TO OPERATE THE CONTROLS
1.Once the unit has power connected, the display should read either “OFF” or the actual pool or spa water temperature. If other than “OFF” or the actual water temperature are displayed, see the “Trouble Shooting” section.
2.If the display reads “OFF”, press the up arrow key until the display reads 60°F or higher.
NOTE: THE DISPLAY READS CURRENT POOL / SPA WATER TEMPERATURE WHEN THE DESIRED TEMPERATURE IS SET TO 60°F OR ABOVE. WHEN THE DESIRED WATER TEMPERATURE IS SET BELOW 60°F
3.Once the unit is displaying the current water temperature, the system is ready to operate. Locate the POOL / SPA selector key on the control panel; by pressing this key, you can select between the pool and spa mode.
4.Using the POOL / SPA selector key, select the pool mode. When the pool mode has been selected, the pool indicator light, located on the left side of the display, will be illuminated.
5.With the control in the pool mode, use the UP / DOWN arrow keys to set the desired pool water temperature.
6.If heater is also being used to heat a spa, repeat the previous two steps to program the desired spa water temperature.
7.The heat pump will now maintain the desired water temperature for the mode selected: POOL, or SPA.
10Not