Arcam A85, P85, P85/3 Service Guide, Build History, Software History, Date, Number, Version

Models: A85

1 54
Download 54 pages 166 b
Page 8
Image 8

 

 

 

 

A85, P85, P85/3 Service Guide

Build History

 

 

 

 

 

 

 

 

 

 

 

 

 

ECO

Date

Description of Change

Number

 

 

 

 

 

 

 

00_1089

 

02/10/00

 

A85 – Fascia position changed to prevent display buttons sticking

00_1129

 

01/11/00

 

A85, P85, P85/3 – Improved stability under heavy clipping of amplifier R345,

 

 

 

 

R346, R445, R446 changed from 100R to 0R link

 

 

 

 

C307, C308, C407, C408 changed from 47P to 100P capacitors

00_1138

 

27/11/00

 

A85, P85, P85/3 – C303, C304, C403 changed from 10uF to 100uf capacitors –

 

 

 

 

this prevents protection circuit from operating when driving a 4 ohm load at

 

 

 

 

low frequency

01_1030

 

23/02/01

 

A85, P85, P85/3 – RV300, RV400 changed to 220R presets to make it easier to

 

 

 

 

adjust the bias settings

01_1068

 

11/04/01

 

A85, P85, P85/3 – New output device clamp fitted to heatsink

01_1101

 

04/06/01

 

A85, P85, P85/3 – Sensitivity of DC offset detection circuit reduced – Power

 

 

 

 

amp cct R308, R408 changed to 22K - R314, R414 changed to 10K

 

 

 

 

PSU surface mount fuse F202 up rated from 500mA to 750mA

01_1142

 

22/08/01

 

A85 – Preamp board upgraded from L866 to L937

01_1178

 

12/10/01

 

A85, P85, P85/3 – Speaker terminals changed from Camcon to 4mm binding

 

 

 

 

post

 

 

 

01_E014

28/11/01

 

A85 – Preamp board fuses F300, F301 up rated to 2A surface mount

02_E033

31/01/02

 

A85 – Extra pad F038 fitted under TX to stop TX coming loose in transit

02_E035

04/02/02

 

A85, P85, P85/3 – Main 20mm fuse rating changed to 4AT

Software History

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECO

 

Date

 

Version

 

Description of Change

Number

 

 

 

 

 

 

 

 

01_1072

 

18/04/01

 

1.1

 

Remote standby action changed from turning unit completely off

 

 

 

 

 

 

to putting unit into standby

01_1095

 

21/05/01

 

1.2

 

Delay added to start H8 start up routine (volume control chip)

01_1167

 

12/09/01

 

1.3

 

Volume chip read/write protocol changed

01_1179

 

26/10/01

 

2.0

 

Added the processor mode option

01_E011

 

23/11/01

 

2.1

 

Corrected the welcome message saving fault. This fault was

 

 

 

 

 

 

introduced with version 2.0 software

02_E048

 

15/02/02

 

2.2

 

Corrected the processor loop volume jump when v/c adjusted

Current Fuse Ratings (20/02/02)

 

 

 

 

 

 

Fuse Position

 

 

 

Fuse Rating

 

Main Supply fuses - A85, P85, P85/3

 

2 x 4AT 20mm (Arcam part number C12406)

 

PSU fuse F202 - A85, P85, P85/3

 

750mA surface mount (Arcam part number C3751)

 

Preamp fuses F300, F301 – A85

 

2A surface mount (Arcam part number C3202)

 

Quiescent Current Setting

 

 

 

 

 

 

 

 

Left channel

 

 

 

Measure points indicated on PCB -

 

 

 

 

 

 

 

 

Adjust RV300 for 8.5mV cold or 12 mV when warm

 

Right channel

 

 

 

Measure points indicated on PCB -

 

 

 

 

 

 

 

 

Adjust RV400 for 8.5mV cold or 12 mV when warm

 

Page 8
Image 8
Arcam A85, P85, P85/3 Service Guide, Build History, Software History, Current Fuse Ratings 20/02/02, Date, Number