Ashly NE 4200.25 manual The Amplifier Control Surface

Models: NE 4200.25

1 16
Download 16 pages 31.54 Kb
Page 11
Image 11
Manual background

Operating Manual - NE Multi Channel Power Amplifier

The Amplifier Control Surface

4)Offset link group - Up to eight groups are available for the purpose of linking similar function parameters across multiple channels. In addition to the control surface secondary level control (not the main fader), most DSP functions have a link group check box in their work window to assign a specific parameter to one of the eight link groups if desired. Link groups can be renamed by clicking on any group name and entering the new name then pressing <enter> on the keyboard.

5)Attenuators - These two dials indicate the physical position of hardware controls on either the amp front panel or the remote level control (if present). Note that these will display the position of attenuators even when DISABLED in software.

6)Total Attenuation - This indicates the total amount of attenuation being applied to the channel. This is the sum of the following attenuators: main fader, offset link group attenuation, front panel and remote attenuators (if enabled).

7)Meters - Input and Output meters display the real time activity per channel, in dB below rated output. Also, the amplifier’s operating temperature and output current are shown. Output current shows that the amplifier channel is actually delivering output to a connected speaker load.

11

Page 11
Image 11
Ashly NE 4200.25 manual The Amplifier Control Surface