Be extremely careful when removing the lamp housing. In the unlikely event that the lamp ruptures, small glass fragments may be generated. The lamp module is designed to contain most of these fragments, but use caution when removing it. Before replacing a ruptured lamp, clean the lamp compartment and dispose of cleaning materials. Wash hands after lamp replacement. This product has a lamp which contains a very small amount of mercury. Dispose of it as required by local, state or fed- eral ordinances and regulations. For more information see www.eiae.org.

5Detach the lamp connector from the projector by gently pulling the con- nector until it is disconnected from the projector.

6Carefully remove the lamp module by grasping and lifting the metal bail wire. Dispose of the lamp in an environmentally proper manner.

7Install the new lamp module, making sure that it is properly seated. Be careful not to touch the interior components of the projector.

8Snap the bail wire back into its flat position against the lamp module.

9Re-attach the lamp connector to the projector. Make sure the connector is fully inserted.

10Tighten the screw on the lamp module.

11Replace the lamp door.

12Plug in the power cable then press the Power button to turn the projec- tor back on, then reset the lamp hour timer.

Resetting the lamp timer

To reset the lamp timer, navigate to the Settings>Service menu and select Reset Lamp Hours.

disconnect lamp connector

remove module using bail wire

reset lamp time in Service menu

34

Page 35
Image 35
Ask Proxima C175 manual Resetting the lamp timer