Rev. A.5, 8/03

Page- 16

installations, the calculation can become quite complex so refer to Appendix B for a more complete discussion.

Distance

Gauge 12V

Gauge 24V

Distance

Gauge 12V

Gauge 24V

 

 

 

 

 

 

80 FT

20 GA

24 GA

800 FT

10 GA

16 GA

 

 

 

 

 

 

200 FT

17 GA

22 GA

1500 FT.

8 GA

14 GA

 

 

 

 

 

 

400 FT

14 GA

20 GA

3000 FT

N/A

12 GA

 

 

 

 

 

 

3.5 SENSTAT MAGNALOCKS: “SC”

Securitron's optional patented Senstat feature provides true lock status sensing. In many electrically controlled door security systems, status sensing is provided by a magnetic switch on the door itself. This indicates the door is closed but not necessarily secured. Securitron's Senstat monitors the lock rather than the door and therefore provides higher security (but note that it can’t be used as an auto-relock input to an access control system).

An “SC” Magnalock provides a dry SPDT output which changes state when the lock is reporting secure (1 Amp @ 30 VDC maximum). This is accomplished by conducting the input power of the lock through the strike and employing it to energize an internal SPDT relay. The white wire is the Senstat relay common. Green is closed to white when the lock is secure and Orange is closed to white when the lock is not secure.

FIG. 15: “SC” SENSTAT WIRING

ORANGE

BLK "SC" LOCK GREEN

POWER

 

 

SUPPLY

RED

WHITE

 

+

 

WHITE AND GREEN WIRES PROVIDE ISOLATED CLOSURE WHEN LOCK IS SECURE. ORANGE AND WHITE ARE CLOSED WHEN LOCK IS NOT SECURE (AS SHOWN ABOVE).

3.6 DOUBLE DOOR PROCEDURE FOR STATUS REPORTING

Often two Magnalocks are mounted on a double door and are turned on and off together (no separate control). As to status reporting, it is of course possible to receive a separate Senstat status signal from each door or you can combine the outputs so that if both locks are secure, the double door is secure and if either lock is not secure, the double door is not secure.

Simply tie the white and green wires together from the two locks. A circuit will be closed between the other white and green wires only when both locks are reporting secure. If either is not secure, the circuit between other white and green wires will be open. The orange wires are not used. See Figure 16.

FIG. 16: DOUBLE DOOR WIRING WITH "SC" LOCKS

WHITE "SC" LOCK GREEN

GREEN "SC" LOCK WHITE

"SC" LOCKS ARE INTERWIRED AS SHOWN TO PROVIDE STATUS MONITORING. AN ISOLATED CLOSURE WILL EXIST BETWEEN THE GREEN AND WHITE WIRES ONLY IF BOTH LOCKS ARE SECURE.