Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Settings

The following items only appears when you set the Console Redirection to [Enabled].

Out-of-Band Mgmt Port [COM1]

Allows remote management of a Windows Server OS through a serial port. Configuration options: [COM1] [COM2]

Terminal Type [VT-UTF8]

 

Allows you to set the terminal type for out-of-band management. Configuration options:

[VT100]

ASCII char set.

[VT100+]

Extends VT100 to support color, function keys, et.

[VT-UTF8]

Uses UTF8 encoding to map Unicode chars onto 1 or more bytes

[ANSI]

Extended ASCII char set

Bits per second [115200]

Selects serial port transmission speed. The speed must be matched on the other side. Long or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400] [57600] [115200]

Flow Control [None]

Allows you to set the flow control to prevent data loss from buffer overflow. Configuration options: [None] [Hardware RTS/CTS] [Software Xon/Xoff]