Allows you to enable or disable the ASUS
The following items may be configured only if the
CPU Target Temperature [45ºC/113ºF]
Allows you to set the target temperature at which the system adjusts the fan speed. Configuration options: [10ºC/50ºF] [15ºC/59ºF] [20ºC/68ºF] [25ºC/77ºF] [30ºC/86ºF] [35ºC/95ºF] [40ºC/104ºF] [45ºC/113ºF] [50ºC/122ºF] [55ºC/131ºF] [60ºC/140ºF] [65ºC/ 149ºF] [70ºC/158ºF] [75ºC/167ºF] [80ºC/176ºF] [85ºC/185ºF]
Temperature Tolerance [3ºC]
Allows you to set the tolerance level of the CPU target temperature. Configuration options: [0ºC] ~ [7ºC]
Minimum FAN Duty Cycle [10/16]
Allows you to set the minimum fan duty cycle.
Configuration options: [0/16] ~ [15/16]
FAN Step Time [0.1 sec]
Allows you to set the time interval to increase or decrease the fan speed. Configuration options: [0.1 sec] ~ [1.6 sec]